Long term measurements of atmospheric nitrogen dioxide (NO2) are performed
using a Fibre Long Path Differential Optical Absorption Spectroscopy (LP-DOAS)
instrument since December 2009 in Hong Kong. The instrument is using a high power
blue LED with peak intensity at 450 nm as the light source to sample a path about 30 m
to 50 m above the street level. Two setups with total absorption paths of 550 m and
3820 m are used in this study. The measurements are used to give better insights in
surface air pollution conditions in Hong Kong. This thesis presents a detailed
description of the instrument setup and the automated data retrieval. The LP-DOAS
measurements were performed in Kowloon Tong and Mong Kok district in Hong Kong.
The measurement results are compared to the concentration from a nearby monitoring
station, operated by the Hong Kong Environmental Protection Department. Hourly
averages of coinciding measurements are in reasonable agreement (R=0.73 on average).
Additionally, NO2 coinciding measurements using the Ozone Monitoring Instrument
(OMI) are compared to the LP-DOAS data. Monthly averaged LP-DOAS and OMI
measurements correlate well (R=0.77). The comparison of mean weekly cycle however,
displays different characteristics. The daily and weekly cycles of NO2 measured by the
LP-DOAS are used to indentify different sources of NO2 in Hong Kong.
| Date of Award | 3 Oct 2011 |
|---|
| Original language | English |
|---|
| Awarding Institution | - City University of Hong Kong
|
|---|
| Supervisor | Mark Oliver WENIG (Supervisor) & Chung Leung Johnny CHAN (Co-supervisor) |
|---|
- Measurement
- Hong Kong
- Optical spectroscopy
- Atmospheric nitrogen dioxide
- China
Atmospheric nitrogen dioxide measurements in Hong Kong using long path differential optical absorption spectroscopy
CHAN, K. L. (Author). 3 Oct 2011
Student thesis: Master's Thesis