The integrated effect of medical lamp position and diffuser discharge velocity on ultra-clean ventilation performance in an operating theatre

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

69 Scopus Citations
View graph of relations

Author(s)

Detail(s)

Original languageEnglish
Pages (from-to)315-331
Journal / PublicationIndoor and Built Environment
Volume15
Issue number4
Publication statusPublished - Aug 2006

Abstract

The ventilation system of an operating theatre (OT) in a hospital needs to provide a comfortable and healthy surgical environment, particularly to minimise the risk of airborne infection. Engineering standards are available to outline specialised ventilation design and installation requirements based on knowledge accumulated from quality research and day-to-day practices. In this paper, the integrated effect of a reduction in supply air velocity and changed medical lamp positions on the ultra-clean ventilation performance of a standard OT environment is reported. The dispersion of infectious particles from both the surgical team and the patient were examined through computational fluid dynamic analysis. It was observed that variations in supply velocity and medical lamp configuration will only slightly affect the thermal comfort environment. However, they could have a serious effect on the movement of infectious particles and hence increase the cross infection risk. © 2006 SAGE Publications.

Research Area(s)

  • Building ventilation, CFD, Indoor airflow, Operating theatre