TY - GEN
T1 - Statistical Piecewise Assembled Model (SPAM) for the representation of highly deformable medical organs
AU - Feng, Jun
AU - Du, Peng
AU - Ip, Horace H.S.
PY - 2008
Y1 - 2008
N2 - We propose a novel Statistical Piecewise Assembled Model (SPAM) to address the open problem of small sample size encountered when applying Point Distribution Models (PDM) in 3-D medical data analysis. Specifically, in our SPAM, the Statistical Frame Model (SFM) constructed from the salient landmarks characterizes the global topological variability of the structure. Then the landmarks are employed to partition a complex object surface into piecewise segments. After that, the Statistical deformable Piecewise surface segment Models (SPMs) are established to define the fine details of local surface shape variations. The hierarchical nature of SPAM enables it to generate much more variation modes than conventional statistical models given a very small sample size training set. The experimental results demonstrate that SPAM can achieve more accuracy rates for model representation compared with traditional Active Shape Model (ASM) and Multi-resolution ASM. © 2008 Springer-Verlag Berlin Heidelberg.
AB - We propose a novel Statistical Piecewise Assembled Model (SPAM) to address the open problem of small sample size encountered when applying Point Distribution Models (PDM) in 3-D medical data analysis. Specifically, in our SPAM, the Statistical Frame Model (SFM) constructed from the salient landmarks characterizes the global topological variability of the structure. Then the landmarks are employed to partition a complex object surface into piecewise segments. After that, the Statistical deformable Piecewise surface segment Models (SPMs) are established to define the fine details of local surface shape variations. The hierarchical nature of SPAM enables it to generate much more variation modes than conventional statistical models given a very small sample size training set. The experimental results demonstrate that SPAM can achieve more accuracy rates for model representation compared with traditional Active Shape Model (ASM) and Multi-resolution ASM. © 2008 Springer-Verlag Berlin Heidelberg.
KW - Organ Representation
KW - Point Distribution Model
KW - Statistical Deformable Model
UR - https://www.scopus.com/pages/publications/50249164892
UR - https://www.scopus.com/pages/publications/50249164892#tab=impact
U2 - 10.1007/978-3-540-79982-5_19
DO - 10.1007/978-3-540-79982-5_19
M3 - RGC 32 - Refereed conference paper (with host publication)
SN - 3540799818
SN - 9783540799818
VL - 5128 LNCS
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 168
EP - 176
BT - Medical Imaging and Augmented Reality
PB - Springer Verlag
T2 - 4th International Workshop on Medical Imaging and Augmented Reality, MIAR 2008
Y2 - 1 August 2008 through 2 August 2008
ER -