TY - JOUR
T1 - Simultaneous use of caustic and oxygen for efficient sulfide control in sewers
AU - Lin, Hui-Wen
AU - Lu, Yang
AU - Ganigué, Ramon
AU - Sharma, Keshab R.
AU - Rabaey, Korneel
AU - Yuan, Zhiguo
AU - Pikaar, Ilje
N1 - Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].
PY - 2017/12/1
Y1 - 2017/12/1
N2 - Periodic caustic shock-loading is a commonly used method for sulfide control in sewers. Caustic shock-loading relies on the elevation of the sewage pH to ≥ 10.5 for several hours, thereby removing sewer pipe biofilms as well as deactivating SRB activity in the remaining biofilm. Although a widely used method, SRB activity is often not completely inhibited, and as such sulfide is still being generated. Here, we propose and experimentally demonstrate an innovative approach which combines caustic with oxygen, another commonly used method, as a dosing strategy for overcoming the drawbacks of caustic shock-loading. Six laboratory-scale rising main reactors were subjected to three dosing schemes over a period of three months, namely (i) simultaneous caustic and oxygen addition, (ii) caustic addition and (iii) no chemical addition. Our results showed that the combination of caustic and oxygen achieved efficient sulfide control, leading to a prolonged biofilm recovery period in between caustic shocks. In addition, methane emissions were reduced to a negligible level compared to caustic treatment only. To translate the findings to real-life application, the key parameters obtained during the long-term lab-scale experiments were subjected to extensive simulation studies using the SeweX model under a wide range of conditions commonly found in sewers. Overall, this study highlights the potential of periodic shock-loading and intermittent oxygen injection as combined dosing strategy for efficient sulfide control in sewers. © 2017 Elsevier B.V.
AB - Periodic caustic shock-loading is a commonly used method for sulfide control in sewers. Caustic shock-loading relies on the elevation of the sewage pH to ≥ 10.5 for several hours, thereby removing sewer pipe biofilms as well as deactivating SRB activity in the remaining biofilm. Although a widely used method, SRB activity is often not completely inhibited, and as such sulfide is still being generated. Here, we propose and experimentally demonstrate an innovative approach which combines caustic with oxygen, another commonly used method, as a dosing strategy for overcoming the drawbacks of caustic shock-loading. Six laboratory-scale rising main reactors were subjected to three dosing schemes over a period of three months, namely (i) simultaneous caustic and oxygen addition, (ii) caustic addition and (iii) no chemical addition. Our results showed that the combination of caustic and oxygen achieved efficient sulfide control, leading to a prolonged biofilm recovery period in between caustic shocks. In addition, methane emissions were reduced to a negligible level compared to caustic treatment only. To translate the findings to real-life application, the key parameters obtained during the long-term lab-scale experiments were subjected to extensive simulation studies using the SeweX model under a wide range of conditions commonly found in sewers. Overall, this study highlights the potential of periodic shock-loading and intermittent oxygen injection as combined dosing strategy for efficient sulfide control in sewers. © 2017 Elsevier B.V.
KW - Caustic shock-loading
KW - Dynamic modelling
KW - Oxygen
KW - Sewer corrosion
KW - Sulfate reducing bacteria
KW - Sulfide abatement
UR - https://www.scopus.com/pages/publications/85020039712
UR - https://www.scopus.com/pages/publications/85020039712#tab=impact
U2 - 10.1016/j.scitotenv.2017.05.225
DO - 10.1016/j.scitotenv.2017.05.225
M3 - RGC 21 - Publication in refereed journal
C2 - 28578235
SN - 0048-9697
VL - 601-602
SP - 776
EP - 783
JO - Science of the Total Environment
JF - Science of the Total Environment
ER -