A single cancer cell was isolated and captured by a microfluidic single-cell biochip. The chip was made of glass and was fabricated by standard photolithography and wet etch process. Simultaneous optical observation and fluorescent measurement were achieved on the captured cancer cell. This was achieved by using red light to observe the cell; whereas the green fluorescent emission was measured photometrically to monitor the drug concentration. A CCD camera was used to image the cell morphology. At the same time, a PMT detector was used to monitor the cellular drug concentrations change in the single cell as a decrease in the cellular fluorescence intensity. Kinetic information of drug concentration change was obtained by analyzing the real time PMT data. This experiment revealed that during the efflux process, the anti-cancer drug (daunorubicin, DNR) decreased as the drug was pumped out of the cell because of multidrug resistance. The reversal effect of a multidrug resistance inhibitor (Sodium orthovanadate, OVN) on the cellular drug retention in single cancer cells was examined in this study. It was found that a higher cellular DNR concentration was resulted when OVN was present. ©2008 Crown.
Original languageEnglish
Title of host publication2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop, IMS3TW
DOIs
Publication statusPublished - 2008
Externally publishedYes
Event2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop, IMS3TW - Vancouver, BC, Canada
Duration: 18 Jun 200820 Jun 2008

Publication series

Name2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop, IMS3TW

Conference

Conference2008 IEEE 14th International Mixed-Signals, Sensors, and Systems Test Workshop, IMS3TW
PlaceCanada
CityVancouver, BC
Period18/06/0820/06/08

Bibliographical note

Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Simultaneous optical and fluorescent microscopic measurement of drug retention in single cancer cells'. Together they form a unique fingerprint.

Cite this