Screening of aptamers on microfluidic systems for clinical applications
Research output: Journal Publications and Reviews › RGC 21 - Publication in refereed journal › peer-review
Author(s)
Detail(s)
Original language | English |
---|---|
Pages (from-to) | 9514-9529 |
Journal / Publication | Sensors (Switzerland) |
Volume | 12 |
Issue number | 7 |
Publication status | Published - Jul 2012 |
Externally published | Yes |
Link(s)
DOI | DOI |
---|---|
Attachment(s) | Documents
Publisher's Copyright Statement
|
Link to Scopus | https://www.scopus.com/record/display.uri?eid=2-s2.0-84864373438&origin=recordpage |
Permanent Link | https://scholars.cityu.edu.hk/en/publications/publication(05332a7b-9578-49f8-bb59-d82a2b0f8912).html |
Abstract
The use of microfluidic systems for screening of aptamers and their biomedical applications are reviewed in this paper. Aptamers with different nucleic acid sequences have been extensively studied and the results demonstrated a strong binding affinity to target molecules such that they can be used as promising candidate biomarkers for diagnosis and therapeutics. Recently, the aptamer screening protocol has been conducted with microfluidic-based devices. Furthermore, aptamer affinity screening by a microfluidic-based method has demonstrated remarkable advantages over competing traditional methods. In this paper, we first reviewed microfluidic systems which demonstrated efficient and rapid screening of a specific aptamer. Then, the clinical applications of screened aptamers, also performed by microfluidic systems, are further reviewed. These automated microfluidic systems can provide advantages over their conventional counterparts including more compactness, faster analysis, less sample/reagent consumption and automation. An aptamer-based compact microfluidic system for diagnosis may even lead to a point-of-care device. The use of microfluidic systems for aptamer screening and diagnosis is expected to continue growing in the near future and may make a substantial impact on biomedical applications. © 2012 by the authors; licensee MDPI, Basel, Switzerland.
Research Area(s)
- Aptamer, Biosensor, MEMS, Microfluidics, SELEX
Bibliographic Note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].
Citation Format(s)
Screening of aptamers on microfluidic systems for clinical applications. / Weng, Chen-Hsun; Huang, Chao-Jyun; Lee, Gwo-Bin.
In: Sensors (Switzerland), Vol. 12, No. 7, 07.2012, p. 9514-9529.
In: Sensors (Switzerland), Vol. 12, No. 7, 07.2012, p. 9514-9529.
Research output: Journal Publications and Reviews › RGC 21 - Publication in refereed journal › peer-review
Download Statistics
No data available