TY - JOUR
T1 - Robust control of dielectric elastomer diaphragm actuator for human pulse signal tracking
AU - Ye, Zhihang
AU - Chen, Zheng
AU - Asmatulu, Ramazan
AU - Chan, Hoyin
PY - 2017/8
Y1 - 2017/8
N2 - Human pulse signal tracking is an emerging technology that is needed in traditional Chinese medicine. However, soft actuation with multi-frequency tracking capability is needed for tracking human pulse signal. Dielectric elastomer (DE) is one type of soft actuating that has great potential in human pulse signal tracking. In this paper, a DE diaphragm actuator was designed and fabricated to track human pulse pressure signal. A physics-based and control-oriented model has been developed to capture the dynamic behavior of DE diaphragm actuator. Using the physical model, an H-infinity robust control was designed for the actuator to reject high-frequency sensing noises and disturbances. The robust control was then implemented in realtime to track a multi-frequency signal, which verified the tracking capability and robustness of the control system. In the human pulse signal tracking test, a human pulse signal was measured at the City University of Hong Kong and then was tracked using DE actuator at Wichita State University in the US. Experimental results have verified that the DE actuator with its robust control is capable of tracking human pulse signal.
AB - Human pulse signal tracking is an emerging technology that is needed in traditional Chinese medicine. However, soft actuation with multi-frequency tracking capability is needed for tracking human pulse signal. Dielectric elastomer (DE) is one type of soft actuating that has great potential in human pulse signal tracking. In this paper, a DE diaphragm actuator was designed and fabricated to track human pulse pressure signal. A physics-based and control-oriented model has been developed to capture the dynamic behavior of DE diaphragm actuator. Using the physical model, an H-infinity robust control was designed for the actuator to reject high-frequency sensing noises and disturbances. The robust control was then implemented in realtime to track a multi-frequency signal, which verified the tracking capability and robustness of the control system. In the human pulse signal tracking test, a human pulse signal was measured at the City University of Hong Kong and then was tracked using DE actuator at Wichita State University in the US. Experimental results have verified that the DE actuator with its robust control is capable of tracking human pulse signal.
KW - Dielectric elastomer
KW - Human pulse signal tracking
KW - Robust control
UR - http://www.scopus.com/inward/record.url?scp=85044537474&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-85044537474&origin=recordpage
U2 - 10.1088/1361-665X/aa75f7
DO - 10.1088/1361-665X/aa75f7
M3 - RGC 21 - Publication in refereed journal
SN - 0964-1726
VL - 26
JO - Smart Materials and Structures
JF - Smart Materials and Structures
IS - 8
M1 - 085043
ER -