Skip to main navigation Skip to search Skip to main content

Reduction of microbial density level in sewage sludge through pH adjustment and ultrasonic treatment

  • D. S. Jean
  • , B. V. Chang
  • , G. S. Liao
  • , G. W. Tsou
  • , D. J. Lee

Research output: Journal Publications and Reviews › RGC 21 - Publication in refereed journal › peer-review

Abstract

This work investigated the effects of using ultrasound and pH-value adjustment on the microbial density levels in sewage sludge, with total coliform and heterotrophic-plate-count (HPC) bacteria as the microbial indices. Application of ultrasound at a high intensity level could sufficiently disinfect both the total coliform and HPC bacteria. Adjustment of pH value could also disinfect the micro-organisms in the sewage sludge, but at a less efficient rate. For the present sewage sludge, the application of ultrasound of 0.33 W/mL level for 1-2 hours could make it a Class B sludge.
Original languageEnglish
Pages (from-to)97-102
JournalWater Science and Technology
Volume42
Issue number9
DOIs
Publication statusPublished - 2000
Externally publishedYes

Bibliographical note

Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].

Research Keywords

  • Microbial density
  • pH values
  • Pre-treatment
  • Ultrasound

Fingerprint

Dive into the research topics of 'Reduction of microbial density level in sewage sludge through pH adjustment and ultrasonic treatment'. Together they form a unique fingerprint.

Cite this