Real-time dynamic analysis for complete loop of direct steam generation solar trough collector
Research output: Journal Publications and Reviews (RGC: 21, 22, 62) › 21_Publication in refereed journal › peer-review
Author(s)
Detail(s)
Original language | English |
---|---|
Pages (from-to) | 573-580 |
Journal / Publication | Energy Conversion and Management |
Volume | 126 |
Publication status | Published - 15 Oct 2016 |
Externally published | Yes |
Link(s)
Abstract
Direct steam generation is a potential approach to further reduce the levelized electricity cost of solar trough. Dynamic modeling of the collector loop is essential for operation and control of direct steam generation solar trough. However, the dynamic behavior of fluid based on direct steam generation is complex because of the two-phase flow in the pipeline. In this work, a nonlinear distribution parameter model has been developed to model the dynamic behaviors of direct steam generation parabolic trough collector loops under either full or partial solar irradiance disturbance. Compared with available dynamic model, the proposed model possesses two advantages: (1) real-time local values of heat transfer coefficient and friction resistance coefficient, and (2) considering of the complete loop of collectors, including subcooled water region, two-phase flow region and superheated steam region. The proposed model has shown superior performance, particularly in case of sensitivity study of fluid parameters when the pipe is partially shaded. The proposed model has been validated using experimental data from Solar Thermal Energy Laboratory of University of New South Wales, with an outlet fluid temperature relative error of only 1.91%. The validation results show that: (1) The proposed model successfully outperforms two reference models in predicting the behavior of direct steam generation solar trough. (2) The model theoretically predicts that, during solar irradiance disturbance, the discontinuities of fluid physical property parameters and the moving back and forth of two-phase flow ending location are the reasons that result in the high-frequency chattering of outlet fluid flow. (3) The model validates that the solar irradiance disturbance at subcooled water region would generates larger fluctuation of fluid parameters than two-phase flow region or superheated steam region. © 2016 Elsevier Ltd
Research Area(s)
- Complete loop, Direct steam generation, Dynamic analysis, Nonlinear distribution parameter model, Real time, Solar trough
Bibliographic Note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to lbscholars@cityu.edu.hk.
Citation Format(s)
Real-time dynamic analysis for complete loop of direct steam generation solar trough collector. / Guo, Su; Liu, Deyou; Chu, Yinghao et al.
In: Energy Conversion and Management, Vol. 126, 15.10.2016, p. 573-580.
In: Energy Conversion and Management, Vol. 126, 15.10.2016, p. 573-580.
Research output: Journal Publications and Reviews (RGC: 21, 22, 62) › 21_Publication in refereed journal › peer-review