Abstract
This paper is concerned with the realization problem for a class of high-pass as well as low-pass transfer functions as a two-port RC ladder network with a specified gain, which requires that the actual gain of the realization configuration is equal to the gain of the given transfer function. From a cascade realization approach, it is shown that any transfer function belonging to the class under investigation can be realized as a two-port RC ladder network with any specified gain in a continuous interval. Finally, a numerical example is presented to illustrate the result.
| Original language | English |
|---|---|
| Pages (from-to) | 1467-1481 |
| Journal | International Journal of Circuit Theory and Applications |
| Volume | 45 |
| Issue number | 11 |
| Online published | 23 Feb 2017 |
| DOIs | |
| Publication status | Published - Nov 2017 |
Research Keywords
- ladder network
- passive network synthesis
- transfer function
- two-port RC network
Fingerprint