TY - JOUR
T1 - Plasma immersion ion implantation into inner and outer races of industrial bearings
AU - Zeng, Z. M.
AU - Kwok, T. K.
AU - Tian, X. B.
AU - Tang, B. Y.
AU - Chu, P. K.
PY - 1999/11
Y1 - 1999/11
N2 - Plasma immersion ion implantation (PIII) is a proven surface treatment technique and can be used to prolong the working lifetime of industrial components. However, the lateral implantation dose uniformity may not be very good, particularly for samples with an irregular shape. In this work, we focus on the PIII treatment of the inner and outer races of industrial bearings. The sheath expansion around the inner and outer races is simulated using a time-dependent, two-dimensional fluid model. The angular and spatial distributions of the incident ions along both the exterior and interior groove surfaces are derived. It is found that the ion dose is the highest on the bottom or center of the groove for both the inner and outer races. The minimum ion dose is near the corner of the groove as the ions impinge at a more glancing incident angle as a result of the ion-matrix sheath evolution. Compared with the exterior groove, the interior groove receives a smaller ion dose in the same implantation time. Our results also indicate that the spatial ion dose uniformity can be improved by reducing the implantation pulse width.
AB - Plasma immersion ion implantation (PIII) is a proven surface treatment technique and can be used to prolong the working lifetime of industrial components. However, the lateral implantation dose uniformity may not be very good, particularly for samples with an irregular shape. In this work, we focus on the PIII treatment of the inner and outer races of industrial bearings. The sheath expansion around the inner and outer races is simulated using a time-dependent, two-dimensional fluid model. The angular and spatial distributions of the incident ions along both the exterior and interior groove surfaces are derived. It is found that the ion dose is the highest on the bottom or center of the groove for both the inner and outer races. The minimum ion dose is near the corner of the groove as the ions impinge at a more glancing incident angle as a result of the ion-matrix sheath evolution. Compared with the exterior groove, the interior groove receives a smaller ion dose in the same implantation time. Our results also indicate that the spatial ion dose uniformity can be improved by reducing the implantation pulse width.
KW - Bearings
KW - Plasma immersion ion implantation
KW - Sheath simulation
KW - Uniformity of implantation dose
UR - http://www.scopus.com/inward/record.url?scp=0033509621&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-0033509621&origin=recordpage
U2 - 10.1016/S0257-8972(99)00433-8
DO - 10.1016/S0257-8972(99)00433-8
M3 - RGC 21 - Publication in refereed journal
SN - 0257-8972
VL - 120-121
SP - 663
EP - 667
JO - Surface and Coatings Technology
JF - Surface and Coatings Technology
ER -