TY - JOUR
T1 - Performance evaluation of low GWP large glide temperature zeotropic mixtures applied in air source heat pump for DHW production
AU - Liu, Jian
AU - Zhou, Lu
AU - Lin, Zhang
AU - Zhang, Xiaosong
PY - 2022/12/15
Y1 - 2022/12/15
N2 - This study proposes the low GWP zeotropic mixtures applied in the air source heat pump for the domestic hot water production using the city water of 15 °C. The large glide temperature in zeotropic mixture side was applied to match temperature lift in hot water side in the condenser. Fifteen zeotropic mixtures, composed of the low boiling compositions (R744, R41, and R170) and high boiling point compositions (RE170, R600a, R1234yf, R1234ze(E), and R290), were compared. A new indicator named temperature match degree (TMD) was applied to evaluate the heat exchanging process. Besides, the system performances, including energy efficiency ratio (EER), exergy efficiency (ηex), volumetric heating capacity (qv, kJ/m3), are evaluated under different conditions. The results showed that the heat pumps using the zeotropic mixtures show better performance than that of the corresponding pure composition, except for qv. The maximum EER, ηex and qv reaches 4.17, 0.472 and 3702 kJ/m3 with the mole fraction of R744/RE170 of 0.3/0.7.TMD was also improved by the zeotropic mixtures, and the maximum TMD reaches 76 % with the mole fraction of RE170/R600a of 0.6/0.4, which is triple for R600a. The results prove the potential of the heat pumps using the large glide temperature zeotropic mixtures applied in domestic hot water production.
AB - This study proposes the low GWP zeotropic mixtures applied in the air source heat pump for the domestic hot water production using the city water of 15 °C. The large glide temperature in zeotropic mixture side was applied to match temperature lift in hot water side in the condenser. Fifteen zeotropic mixtures, composed of the low boiling compositions (R744, R41, and R170) and high boiling point compositions (RE170, R600a, R1234yf, R1234ze(E), and R290), were compared. A new indicator named temperature match degree (TMD) was applied to evaluate the heat exchanging process. Besides, the system performances, including energy efficiency ratio (EER), exergy efficiency (ηex), volumetric heating capacity (qv, kJ/m3), are evaluated under different conditions. The results showed that the heat pumps using the zeotropic mixtures show better performance than that of the corresponding pure composition, except for qv. The maximum EER, ηex and qv reaches 4.17, 0.472 and 3702 kJ/m3 with the mole fraction of R744/RE170 of 0.3/0.7.TMD was also improved by the zeotropic mixtures, and the maximum TMD reaches 76 % with the mole fraction of RE170/R600a of 0.6/0.4, which is triple for R600a. The results prove the potential of the heat pumps using the large glide temperature zeotropic mixtures applied in domestic hot water production.
UR - http://www.scopus.com/inward/record.url?scp=85141996411&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-85141996411&origin=recordpage
U2 - 10.1016/j.enconman.2022.116457
DO - 10.1016/j.enconman.2022.116457
M3 - RGC 21 - Publication in refereed journal
SN - 0196-8904
VL - 274
JO - Energy Conversion and Management
JF - Energy Conversion and Management
M1 - 116457
ER -