Skip to main navigation Skip to search Skip to main content

Online Condition Monitoring of Bond Wire Lift-Off in SiC MOSFETs Using Discrete Transmission Line Response to Gate Resistor Voltage in SiC MOSFET

Research output: Chapters, Conference Papers, Creative and Literary Works › RGC 32 - Refereed conference paper (with host publication) › peer-review

Abstract

This article presents a novel online condition monitoring technique for SiC MOSFET bond wire lift-off. A discrete transmission line (DTL), connected in parallel with the gate resistor, serves as a sensing medium. The DTL is specifically tuned to be highly sensitive to the resonant network formed by the MOSFET's intrinsic source inductance and gate-source capacitance. An increase in source inductance from bond wire degradation alters the DTL's standing wave pattern, providing a clear failure indicator. The method uniquely decouples inductance and capacitance variations by analyzing the DTL's high- and low- frequency responses. Validated on a 500W, 100kHz buck converter using an emulated fault, experimental results showed excellent agreement with theory, confirming the technique's effectiveness. © 2026 IEEE.
Original languageEnglish
Title of host publication2026 IEEE Applied Power Electronics Conference and Exposition (APEC)
PublisherIEEE
Pages3432-3436
Number of pages5
ISBN (Electronic)979-8-3315-7544-1
DOIs
Publication statusPublished - 2026
Event41st IEEE Applied Power Electronics Conference and Exposition (APEC 2026) - Henry B. González Convention Center, San Antonio, United States
Duration: 22 Mar 2026 → 26 Mar 2026
https://apec-conf.org/wp-content/uploads/2026/03/APEC-2026-Program-Book-20260223.pdf

Publication series

NameConference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
Volume2026-March
ISSN (Print)1048-2334
ISSN (Electronic)2470-6647

Conference

Conference41st IEEE Applied Power Electronics Conference and Exposition (APEC 2026)
PlaceUnited States
CitySan Antonio
Period22/03/26 → 26/03/26
Internet address

Funding

This work was supported by the Innovation and Technology Fund from the Hong Kong Special Administrative Region, China, under Project #MRP/010/21X.

Research Keywords

  • bond wire lift-off
  • diagnosis
  • online condition monitoring
  • SiC MOSFET