Skip to main navigation Skip to search Skip to main content

Nonrigid registration of carotid ultrasound and MR images using a "twisting and bending" model

  • Nuwan D. Nanayakkara
  • , Bernard Chiu
  • , Abbas Samani
  • , J. David Spence
  • , Grace Parraga
  • , Jagath Samarabandu
  • , Aaron Fenster

Research output: Chapters, Conference Papers, Creative and Literary WorksRGC 32 - Refereed conference paper (with host publication)peer-review

Abstract

Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Plaque composition information from magnetic resonance (MR) carotid images and dynamic characteristics information from 3D ultrasound (US) are necessary for developing and validating US imaging tools to identify vulnerable carotid plaques. Combining these images requires nonrigid registration to correct the non-linear miss-alignments caused by relative twisting and bending in the neck due to different head positions during the two image acquisitions sessions. The high degree of freedom and large number of parameters associated with existing nonrigid image registration methods causes several problems including unnatural plaque morphology alteration, computational complexity, and low reliability. Our approach was to model the normal movement of the neck using a "twisting and bending model" with only six parameters for nonrigid registration. We evaluated our registration technique using intra-subject in-vivo 3D US and 3D MR carotid images acquired on the same day. We calculated the Mean Registration Error (MRE) between the segmented vessel surfaces in the target image and the registered image using a distance-based error metric after applying our "twisting bending model" based nonrigid registration algorithm. We achieved an average registration error of 1.33 ± 0.41mm using our nonrigid registration technique. Visual inspection of segmented vessel surfaces also showed a substantial improvement of alignment with our non-rigid registration technique.
Original languageEnglish
Title of host publicationProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6914
DOIs
Publication statusPublished - 2008
Externally publishedYes
EventMedical Imaging 2008: Image Processing - San Diego, CA, United States
Duration: 17 Feb 200819 Feb 2008

Publication series

Name
Volume6914
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2008: Image Processing
PlaceUnited States
CitySan Diego, CA
Period17/02/0819/02/08

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Research Keywords

  • Carotid plaque
  • Magnetic resonance (MR)
  • Registration
  • Ultrasound

Fingerprint

Dive into the research topics of 'Nonrigid registration of carotid ultrasound and MR images using a "twisting and bending" model'. Together they form a unique fingerprint.

Cite this