Modeling of the Cuffless Blood Pressure Measurement Errors for the Evaluation of a Wearable Medical Device

Research output: Chapters, Conference Papers, Creative and Literary Works › RGC 32 - Refereed conference paper (with host publication) › peer-review

Abstract

The two widely used standards for validating the conventional cuff-based BP devices are those set up by the American Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) respectively. It was reported that although both standards work well for most BP devices, they do not agree with each other in all circumstances. Previous attempts to model the measurement errors as Gaussian could not explain the phenomena. Results of this study indicate that the general t distribution fits better to the BP measurement errors reported in previous literatures and collected from our clinical experiments. Furthermore, the theoretical mapping of the AAMI accuracy criteria and BHS grading system derived from the t distribution model can better reflect the real situations, where some devices can pass the BBS criteria but fail that of the AAMI. Based on this mapping relationship, it is found that current standards work well for devices with error distribution close to Gaussian but they may not be suitable for the newly developed wearable BP measuring devices used in the experiment, where the errors followed a t distribution with a smaller degree of freedom. It is suggested that a statistical measure that takes into account both the probability and the absolute value of the extreme errors could be introduced into the standard in order to better evaluate this kind of wearable, cuffless BP measuring devices.
Original languageEnglish
Title of host publicationProceedings of the 3rd IEEE-EMBS International Summer School and Symposium on Medical Devices and Biosensors (ISSS-MDBS 2006)
Subtitle of host publicationTheme: "Wearable Body Sensor Networks and E-Textile Solutionsfor M-Health"
PublisherIEEE
Pages105-108
ISBN (Electronic)0780397878
ISBN (Print)078039786X
DOIs
Publication statusPublished - Sept 2006
Externally publishedYes
EventThe 3rd IEEE-EMBS International Summer School and Symposium on Medical Devices and Biosensors (ISSS-MDBS 2006): Theme: "Wearable Body Sensor Networks and E-Textile Solutionsfor M-Health"  - Massachusetts Institute of Technology, Cambridge, United States
Duration: 4 Sept 2006 → 6 Sept 2006
https://ieeexplore.ieee.org/xpl/conhome/4201240/proceeding

Publication series

NameProceedings of the ... IEEE-EMBS International Summer School and Symposium on Medical Devices and Biosensors

Conference

ConferenceThe 3rd IEEE-EMBS International Summer School and Symposium on Medical Devices and Biosensors (ISSS-MDBS 2006)
PlaceUnited States
CityCambridge
Period4/09/06 → 6/09/06
Internet address

Fingerprint

Dive into the research topics of 'Modeling of the Cuffless Blood Pressure Measurement Errors for the Evaluation of a Wearable Medical Device'. Together they form a unique fingerprint.

Cite this