Abstract
To minimize pyroelectric effects while keeping high piezoelectric effects in relaxor-PbTiO3 single crystals, the crystallographic orientation dependence of the pyroelectric and piezoelectric coefficients were investigated for binary (1 - x)Pb(Mg1/3Nb2/3)O3-xPbTiO 3 (PMN-PT), ternary (1 - x - y)Pb(In1/2Nb 1/2)O3-yPb(Mg1/3Nb2/3)O 3-xPbTiO3 (PIN-PMN-PT) and Mn-doped PIN-PMN-PT single crystals with the "4R" multidomain state. The secondary pyroelectric coefficients were calculated from the thermodynamic inter-relationship between the piezoelectric, elastic, and thermal expansion coefficients, being on the order of (1.16-1.23) × 10-4 C m-2 K-1 for binary crystals and (0.97-2.03) × 10-4 C m-2 K -1 for ternary ones. The primary pyroelectric coefficients were -(6.73-6.84) × 10-4 C m-2 K-1 and -(5.44-6.43) × 10-4 C m-2 K-1 for binary and ternary crystals, respectively. The pyroelectric coefficients could be reduced by matrix rotation, but at the cost of decreasing longitudinal piezoelectric coefficients d33. Of particular interest is that the maximum piezoelectric coefficients d24â̂ - at θ = ±55o and d34â̂ - at θ = ±35 o by a counterclockwise rotation of θ about the X axis (θ is the rotation angle about the coordinate axes), or d15â̂ - at θ = ±55o, and d35â̂ - at θ = ±35o by a counterclockwise rotation the Y axis, were found on the order of 3000 pC N-1. The corresponding pyroelectric coefficients could be reduced by ∼20%. The reduced pyroelectric coefficients that can contribute to decrease undesirable output signals, together with the high piezoelectric coefficients, enable relaxor-PT crystals as favorable candidates for high-sensitivity piezoelectric sensors. © 2014 Elsevier B.V.
| Original language | English |
|---|---|
| Pages (from-to) | 135-140 |
| Journal | Materials Chemistry and Physics |
| Volume | 145 |
| Issue number | 1-2 |
| DOIs | |
| Publication status | Published - 15 May 2014 |
| Externally published | Yes |
Bibliographical note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].Funding
This work is supported by ONR and Science and Technology Commission of Shanghai Municipality (Grant No. 13ZR1430200 ). The author (Y. Tang) would like to thank China Scholarship Council for the financial support of exchange scholar.
Research Keywords
- Domain structure
- Electronic materials
- Piezoelectric
- Pyroelectric
Fingerprint
Dive into the research topics of 'Minimization of pyroelectric effects in relaxor-PbTiO3 crystals for piezoelectric sensors'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver