Microfluidic imaging flow cytometry by asymmetric-detection time-stretch optical microscopy (ATOM)

  • Anson H. L. Tang
  • , Queenie T. K. Lai
  • , Bob M. F. Chung
  • , Kelvin C. M. Lee
  • , Aaron T. Y. Mok
  • , G. K. Yip
  • , Anderson H. C. Shum
  • , Kenneth K. Y. Wong
  • , Kevin K. Tsia*
  • *Corresponding author for this work

Research output: Journal Publications and Reviews › RGC 21 - Publication in refereed journal › peer-review

Abstract

Scaling the number of measurable parameters, which allows for multidimensional data analysis and thus higher-confidence statistical results, has been the main trend in the advanced development of flow cytometry. Notably, adding high-resolution imaging capabilities allows for the complex morphological analysis of cellular/sub-cellular structures. This is not possible with standard flow cytometers. However, it is valuable for advancing our knowledge of cellular functions and can benefit life science research, clinical diagnostics, and environmental monitoring. Incorporating imaging capabilities into flow cytometry compromises the assay throughput, primarily due to the limitations on speed and sensitivity in the camera technologies. To overcome this speed or throughput challenge facing imaging flow cytometry while preserving the image quality, asymmetric-detection time-stretch optical microscopy (ATOM) has been demonstrated to enable high-contrast, single-cell imaging with sub-cellular resolution, at an imaging throughput as high as 100,000 cells/s. Based on the imaging concept of conventional time-stretch imaging, which relies on all-optical image encoding and retrieval through the use of ultrafast broadband laser pulses, ATOM further advances imaging performance by enhancing the image contrast of unlabeled/unstained cells. This is achieved by accessing the phase-gradient information of the cells, which is spectrally encoded into single-shot broadband pulses. Hence, ATOM is particularly advantageous in high-throughput measurements of single-cell morphology and texture – information indicative of cell types, states, and even functions. Ultimately, this could become a powerful imaging flow cytometry platform for the biophysical phenotyping of cells, complementing the current state-of-the-art biochemical-marker-based cellular assay. This work describes a protocol to establish the key modules of an ATOM system (from optical frontend to data processing and visualization backend), as well as the workflow of imaging flow cytometry based on ATOM, using human cells and microalgae as the examples. © 2017 Journal of Visualized Experiments.
Original languageEnglish
Article numbere55840
JournalJournal of Visualized Experiments
Volume2017
Issue number124
DOIs
Publication statusPublished - 28 Jun 2017
Externally publishedYes

Bibliographical note

Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].

Funding

We thank Mr. P. Yeung for preparing the MCF-7 for us. This work was partially supported by grants from the Research Grant Council of the Hong Kong Special Administration Region, China (Project no. 17259316, 17207715, 17207714, 17205215, and HKU 720112E), the Innovation and Technology Support Programme (ITS/090/14), and the University Development Fund of HKU.

Research Keywords

  • Engineering
  • High-throughput screening
  • Imaging flow cytometry
  • Issue 124
  • Microfluidic
  • Microscopy
  • Single-cell analysis
  • Time-stretch imaging