TY - JOUR
T1 - Microchip and capillary electrophoresis for quantitative analysis of hepatitis C virus based on RT-competitive PCR
AU - Young, Kung-Chia
AU - Lien, Hsiang-Mei
AU - Lin, Chun-Che
AU - Chang, Ting-Tsung
AU - Lee, Gwo-Bin
AU - Chen, Shu-Hui
PY - 2002/2/11
Y1 - 2002/2/11
N2 - A method to quantitatively perform reverse transcription-competitive PCR (RT-cPCR) of hepatitis C virus followed by both microchip and capillary electrophoretic separation and detection was described. In this method, HCV wild-type (WT) RNA extracted from serum was coretrotranscribed and coamplified with a constant amount of recombinant internal standard (IS) RNA which had the same primer binding region as the target RNA and was constructed by removing a centrally located 25-bp segment from the target template. A linear calibration curve was constructed by adding IS RNA at a constant concentration of 8000 copies μl-1 into a series of RNA target standards ranging from 400 to 106 copies μl-1. The amplified IS and target DNA were detected by both capillary and microchip electrophoresis via laser-induced fluorescence (LIF) using Cy5-labelled primer as the fluorescence probe. The method was further demonstrated for the quantitation of clinical patients with low, medium, and high viral titer and the results were found to be comparable to those determined by the commercial bDNA assay. © 2002 Elsevier Science B.V. All rights reserved.
AB - A method to quantitatively perform reverse transcription-competitive PCR (RT-cPCR) of hepatitis C virus followed by both microchip and capillary electrophoretic separation and detection was described. In this method, HCV wild-type (WT) RNA extracted from serum was coretrotranscribed and coamplified with a constant amount of recombinant internal standard (IS) RNA which had the same primer binding region as the target RNA and was constructed by removing a centrally located 25-bp segment from the target template. A linear calibration curve was constructed by adding IS RNA at a constant concentration of 8000 copies μl-1 into a series of RNA target standards ranging from 400 to 106 copies μl-1. The amplified IS and target DNA were detected by both capillary and microchip electrophoresis via laser-induced fluorescence (LIF) using Cy5-labelled primer as the fluorescence probe. The method was further demonstrated for the quantitation of clinical patients with low, medium, and high viral titer and the results were found to be comparable to those determined by the commercial bDNA assay. © 2002 Elsevier Science B.V. All rights reserved.
KW - Competitive PCR
KW - Hepatitis C virus (HCV)
KW - Microchip electrophoresis
KW - Quantitation
UR - http://www.scopus.com/inward/record.url?scp=0037060165&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-0037060165&origin=recordpage
U2 - 10.1016/S0039-9140(01)00598-7
DO - 10.1016/S0039-9140(01)00598-7
M3 - RGC 21 - Publication in refereed journal
SN - 0039-9140
VL - 56
SP - 323
EP - 330
JO - Talanta
JF - Talanta
IS - 2
ER -