Abstract
The centrifugal settling expression, differential scanning calorimetry (DSC), and drying tests are employed for measuring the bound water content in a sludge made of CaCO3, PVC, or glass powders, an inorganic Cu(OH)2 sludge, and an activated sludge. The bound water is found to be an operationally defined value that differs greatly when different measurement technique is applied. A classification scheme for dividing the moisture content in a sludge based on the bound water data is proposed.
| Original language | English |
|---|---|
| Pages (from-to) | 310-317 |
| Journal | Water Environment Research |
| Volume | 67 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - 1995 |
| Externally published | Yes |
Bibliographical note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 6 Clean Water and Sanitation
Research Keywords
- bound water
- centrifuge
- drying
- settling
Fingerprint