Long-term measurements of radon progeny concentrations with solid-state nuclear track detectors

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

45 Scopus Citations
View graph of relations

Author(s)

  • K.N. Yu
  • D. Nikezic
  • F.M.F. Ng
  • J.K.C. Leung

Detail(s)

Original languageEnglish
Pages (from-to)560-568
Journal / PublicationRadiation Measurements
Volume40
Issue number2-6
Online published28 Jul 2005
Publication statusPublished - Nov 2005

Conference

Title22nd International Conference on Nuclear Tracks in Soils (ICNTS 22)
LocationUniversitat Autònoma de Barcelona
PlaceSpain
CityBarcelona
Period23 - 27 August 2004

Abstract

In this paper, we review existing methods for long-term measurements of radon decay products with solid-state nuclear track detectors. We then propose a method to determine the equilibrium factor using the bare LR 115 detector. The partial sensitivities pi of the LR 115 detector to 222Rn and its α-emitting short-lived progeny, 218Po and 214Po, were investigated. We determined the distributions of lengths of major and minor axes of the perforated α-tracks in the LR 115 detector produced by 222Rn, 218Po and 214Po through Monte Carlo simulations. The track parameters were first calculated using a track development model with a published V function, and by assuming a removed active layer of 6.54μm. The distributions determined for different α-emitters were found to be completely overlapping with one another. This implied equality of partial sensitivities for radon and its progeny. Equality of partial sensitivities makes convenient measurements of a proxy equilibrium factor Fp possible which is defined in the present work as (f1+f3) and is equal to the ratio between the sum of concentrations of the two α-emitting radon progeny (218Po + 214Po) to the concentration of radon gas (222Rn). In particular, we have found Fp=(ρ/ρitC0)-1, where ρ (track/m2) is the total track density on the detector, ρi=0.288×10-2m (for the V function mentioned above and for a removed active layer of 6.54μm), t is the exposure time and C0 (Bq/m3) is the concentration of 222Rn. If C0 is known (e.g., from a separate measurement), we can obtain Fp. The proxy equilibrium factor Fp is also found to be well correlated with the equilibrium factor between radon gas and its progeny through the Jacobi room model. This leads to a novel method for long-term determination of the equilibrium factor. Experimental irradiation of LR 115 detectors to known 222Rn concentrations as well as known equilibrium factors were carried out to verify the present method. The relationship between ρi and the removed layer was then derived for the V function specifically determined for the LR 115 detectors we were using for the experiments. The actual removed layers for individual detectors after etching were measured accurately using surface profilometry. A curve showing the relationship between the removed layer and the track diameter of normally incident 3 MeV α-particles is also provided for other researchers, who do not have access to surface profilometry, to use the present technique conveniently.

Research Area(s)

  • Equilibrium factor, LR 115 detector, Radon progeny concentration

Citation Format(s)

Long-term measurements of radon progeny concentrations with solid-state nuclear track detectors. / Yu, K.N.; Nikezic, D.; Ng, F.M.F. et al.
In: Radiation Measurements, Vol. 40, No. 2-6, 11.2005, p. 560-568.

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review