Abstract
Local measurements of flow parameters were performed for vertical upward subcooled boiling flows in an internally heated annulus. The annulus channel consisted of an inner heater rod with a diameter of 19.0mm and an outer round tube with an inner diameter of 37.5mm, and the hydraulic equivalent diameter was 18.5 mm. The double-sensor conductivity probe method was used for measuring the local void fraction, interfacial area concentration, bubble Sauter mean diameter and gas velocity, whereas the miniature Pitot tube was used for measuring the local liquid velocity. A total of 32 data sets were acquired consisting of various combinations of heat flux, 88.1–350.9 kW/m2, mass flux, 469.7–1061.4 kg/(m2 s) and inlet liquid temperature, 83.8–100.5°C. Six existing drift-flux models, six existing correlations of the interfacial area concentration and bubble layer thickness model were evaluated using the data obtained in the experiment. © 2008 Taylor and Francis Group, LLC.
| Original language | English |
|---|---|
| Pages (from-to) | 683-697 |
| Journal | Journal of Nuclear Science and Technology |
| Volume | 45 |
| Issue number | 7 |
| DOIs | |
| Publication status | Published - Jul 2008 |
| Externally published | Yes |
Bibliographical note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].Research Keywords
- Conductivity probe
- Constitutive equation
- Drift-flux model
- Interfacial area concentration
- Internally heated annulus
- Liquid velocity
- Pitot tube
- Subcooled boiling flow
- Two-fluid model
- Void fraction