Abstract
Titanium oxide film with a graded interface to NiTi matrix was synthesized in situ on NiTi shape memory alloy(SMA) by oxidation in H2O2 solution. In vitro studies including contact angle measurement, hemolysis, MTT cytotoxicity and cell morphology tests were employed to investigate the biocompatibility of the H2O2-oxidized NiTi SMAs with this titanium oxide film. The results reveal that wettability, blood compatibility and fibroblasts compatibility of NiTi SMA are improved by the coating of titanium oxide film through H2O2 oxidation treatment. © 2007 The Nonferrous Metals Society of China.
| Original language | English |
|---|---|
| Pages (from-to) | 553-557 |
| Journal | Transactions of Nonferrous Metals Society of China (English Edition) |
| Volume | 17 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - Jun 2007 |
Research Keywords
- biocompatibility
- cytocompatibility
- NiTi shape memory alloy
- titanium oxide film
- wettability
Fingerprint