Improved corrosion resistance of plasma carbon coated NiTi orthopedic materials
Research output: Journal Publications and Reviews › RGC 22 - Publication in policy or professional journal
Author(s)
Detail(s)
Original language | English |
---|---|
Article number | 5P43 |
Journal / Publication | IEEE International Conference on Plasma Science |
Publication status | Published - 2004 |
Conference
Title | 31st IEEE International Conference on Plasma Science (ICOPS2004) |
---|---|
Place | United States |
City | Baltimore |
Period | 28 June - 1 July 2004 |
Link(s)
Abstract
Nickel titanium (NiTi) alloys are useful in orthopedic applications because of their super-elastic properties and shape memory effects. However, when NiTi is used for a prolonged period of time, harmful Ni ions can leach out into the surrounding body fluid inside a human body, and so it is important to design a method to impede the out-diffusion of nickel from the materials into the biological medium. We aim at producing a barrier to mitigate the release of Ni ions during normal use. Carbon coatings have been shown to possess excellent bio-compatibility and good mechanical strength. In this work, amorphous hydrogenated DLC films with a graded C/NiTi interface were fabricated by plasma immersion ion implantation & deposition (PU & D) to provide such a barrier layer on NiTi. The elemental depth profiles and film thickness were determined by X-ray photoelectron spectroscopy (XPS) whereas the surface morphology was evaluated using atomic force microscopy (AFM). The film structure was studied by X-ray diffraction (XRD) and Raman spectroscopy. The corrosion resistance of the film was investigated using electrochemical tests based on ASTM G5-94. Compared to the control sample, the corrosion potential of the sample with the carbon coating changes from -250 to -50 mV and the film breakdown potential increases from 250 to 1200 mV. The corrosion current also diminishes from 10-6 to 10-7 A. The simulated body fluid (SBF) solutions after the electrochemical test were analyzed for Ni concentrations by inductively-coupled plasma mass spectrometry (ICPMS) and that data show that a much smaller amount of Ni has been released from the treated sample surface compared to the untreated control sample surface. Our results thus indicate that the deposited DLC film is effective in retarding the release of Ni ions from the bulk materials and more superior corrosion resistance is achieved based on our tests in a simulated fluid medium and at human body temperature.
Citation Format(s)
Improved corrosion resistance of plasma carbon coated NiTi orthopedic materials. / Poon, R. W Y; Liu, X. Y.; Chung, C. Y. et al.
In: IEEE International Conference on Plasma Science, 2004.
In: IEEE International Conference on Plasma Science, 2004.
Research output: Journal Publications and Reviews › RGC 22 - Publication in policy or professional journal