Skip to main navigation Skip to search Skip to main content

Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation

  • Xiaorong Ding
  • , Yuanting Zhang
  • , Hon Ki Tsang*
  • *Corresponding author for this work

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

Abstract

Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.
Original languageEnglish
Pages (from-to)227-237
JournalPhysiological Measurement
Volume37
Issue number2
Online published15 Jan 2016
DOIs
Publication statusPublished - Feb 2016
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Research Keywords

  • blood pressure
  • calibration interval
  • estimation accuracy
  • heart disease
  • pulse transit time

Fingerprint

Dive into the research topics of 'Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation'. Together they form a unique fingerprint.