TY - JOUR
T1 - Image fusion enhancement of deformable human structures using a two-stage warping-deformable strategy
T2 - A content-based image retrieval consideration
AU - Tang, Fuk-Hay
AU - Horace Ip, H. S.
PY - 2009/9
Y1 - 2009/9
N2 - In medical image registration and content-based image retrieval, the rigid transformation model is not adequate for anatomical structures that are elastic or deformable. For human structures such as abdomen, registration would involve global features such as abdominal wall as well as local target organs such as liver or spleen. A general non-rigid registration may not be sufficient to produce image matching of both global and local structures. In this study, a warping-deformable model is proposed to register images of such structures. This model uses a two-stage strategy for image registration of abdomen. In the first stage, the global-deformable transformation is used to register the global wall. The warping-transformation is used in second stage to register the liver. There is a good match of images using the proposed method (mean similarity index∈=∈0.73545).The image matching correlation coefficients calculated from eight pairs of CT and MR images of abdomen indicates that the warping-deformable transformation gives better matching of images than those without transformation (p∈
AB - In medical image registration and content-based image retrieval, the rigid transformation model is not adequate for anatomical structures that are elastic or deformable. For human structures such as abdomen, registration would involve global features such as abdominal wall as well as local target organs such as liver or spleen. A general non-rigid registration may not be sufficient to produce image matching of both global and local structures. In this study, a warping-deformable model is proposed to register images of such structures. This model uses a two-stage strategy for image registration of abdomen. In the first stage, the global-deformable transformation is used to register the global wall. The warping-transformation is used in second stage to register the liver. There is a good match of images using the proposed method (mean similarity index∈=∈0.73545).The image matching correlation coefficients calculated from eight pairs of CT and MR images of abdomen indicates that the warping-deformable transformation gives better matching of images than those without transformation (p∈
KW - Deformable
KW - Fusion
KW - Image registration
KW - Matching
KW - Warping
UR - http://www.scopus.com/inward/record.url?scp=68749115135&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-68749115135&origin=recordpage
U2 - 10.1007/s10796-009-9151-6
DO - 10.1007/s10796-009-9151-6
M3 - RGC 21 - Publication in refereed journal
SN - 1387-3326
VL - 11
SP - 381
EP - 389
JO - Information Systems Frontiers
JF - Information Systems Frontiers
IS - 4
ER -