TY - JOUR
T1 - HOPF BIFURCATION AS AN INTERMEDIATE-SCALE INSTABILITY IN SINGLE-STAGE POWER-FACTOR-CORRECTION POWER SUPPLIES
T2 - ANALYSIS, SIMULATIONS AND EXPERIMENTAL VERIFICATION
AU - DAI, DONG
AU - TSE, CHI K.
AU - ZHANG, BO
AU - MA, XIKUI
PY - 2008/7
Y1 - 2008/7
N2 - This paper reports intermediate-scale instability in a single-stage power-factor-correction (PFC) power supply that employs a cascade configuration of a boost stage operating in discontinuous conduction mode (DCM) and a forward stage operating in continuous conduction mode (CCM). The two stages combine into a single stage by sharing one main switch and one control loop to achieve input PFC and tight output regulation. The main results are given by "exact" cycle-by-cycle circuit simulations. The effect of the intermediate-scale instability on the attainable power factor is illustrated in terms of total harmonic distortion (THD) which is found by taking the Fast Fourier Transform (FFT) of the input current. The intermediate-scale instability usually manifests itself as local oscillations within a line cycle. Based on the stability analysis of a buck converter operating in CCM, the underlying mechanism of such instability can be attributed to the Hopf bifurcation that occurred in CCM forward stage. Finally, experimental results are presented for verification purposes. © 2008 World Scientific Publishing Company.
AB - This paper reports intermediate-scale instability in a single-stage power-factor-correction (PFC) power supply that employs a cascade configuration of a boost stage operating in discontinuous conduction mode (DCM) and a forward stage operating in continuous conduction mode (CCM). The two stages combine into a single stage by sharing one main switch and one control loop to achieve input PFC and tight output regulation. The main results are given by "exact" cycle-by-cycle circuit simulations. The effect of the intermediate-scale instability on the attainable power factor is illustrated in terms of total harmonic distortion (THD) which is found by taking the Fast Fourier Transform (FFT) of the input current. The intermediate-scale instability usually manifests itself as local oscillations within a line cycle. Based on the stability analysis of a buck converter operating in CCM, the underlying mechanism of such instability can be attributed to the Hopf bifurcation that occurred in CCM forward stage. Finally, experimental results are presented for verification purposes. © 2008 World Scientific Publishing Company.
KW - Power factor correction (PFC)
KW - Single-stage PFC power supply
KW - Intermediate-scale instability
KW - Hopf bifurcation
UR - http://www.scopus.com/inward/record.url?scp=52149089204&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-52149089204&origin=recordpage
U2 - 10.1142/S0218127408021592
DO - 10.1142/S0218127408021592
M3 - RGC 21 - Publication in refereed journal
SN - 0218-1274
VL - 18
SP - 2095
EP - 2109
JO - International Journal of Bifurcation and Chaos
JF - International Journal of Bifurcation and Chaos
IS - 7
ER -