Skip to main navigation Skip to search Skip to main content

Experimental study of air distribution and heating performances of deflection ventilation

  • Fanghui Cheng
  • , Yunhao Li
  • , Yuxin Wu
  • , Yong Cheng*
  • , Zhang Lin
  • *Corresponding author for this work

    Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

    Abstract

    Deflection ventilation uses a purposely-designed deflector to divert supply air jet into the occupied zone directly. A few numerical studies have shown good indoor air quality with deflection ventilation. However, there was a lack of research on thermal comfort, which is also important to ensure human wellbeing. This study conducted experimental measurements when deflection ventilation was operated for winter heating. Eleven cases with different supply air velocities, supply air temperatures and deflection angles were carried out in an office-layout experimental chamber. As a comparison, another case with mixing ventilation was also measured. The predicted mean vote (PMV), draft rate (DR), air diffusion performance index (ADPI) and energy utilization coefficient (EUC) were adopted to evaluate the heating performances. The results showed that the deflection angle played a decisive role on air distribution. An inclined deflector (deflection angle: 35° downward) could elevate air temperature in the lower occupied zone as compared with a horizontal deflector (deflection angle: 0°), which provided efficient air distribution for winter heating. The average PMV values were in the range of −0.7 – 0.5, and the values of DR and ADPI in the occupied zone were typically less than 20% and higher than 80%, respectively. According to ISO 7730 and ASHRAE 113, deflection ventilation achieved satisfactory indoor environment with regard to thermal comfort. The EUC was typically greater than unity, indicating high energy efficiency of deflection ventilation, especially for the cases with deflection angle of 35°. In comparison with mixing ventilation, deflection ventilation can provide better thermal comfort as well as energy efficiency.
    Original languageEnglish
    Article number112800
    JournalEnergy and Buildings
    Volume282
    Online published11 Jan 2023
    DOIs
    Publication statusPublished - 1 Mar 2023

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 7 - Affordable and Clean Energy
      SDG 7 Affordable and Clean Energy
    2. SDG 9 - Industry, Innovation, and Infrastructure
      SDG 9 Industry, Innovation, and Infrastructure
    3. SDG 12 - Responsible Consumption and Production
      SDG 12 Responsible Consumption and Production

    Research Keywords

    • Air distribution
    • Deflection ventilation
    • Energy utilization coefficient
    • Thermal comfort
    • Winter heating

    Fingerprint

    Dive into the research topics of 'Experimental study of air distribution and heating performances of deflection ventilation'. Together they form a unique fingerprint.

    Cite this