N2 - The performance of the solar water heater varies with respect to incident solar radiation, geographical location, and components of the solar water heater such as glazing, absorber material and storage tank. In this work, building-integrated solar water heating system (BISWHS) is fabricated and its output is evaluated by installing it on the roof and façade of the building for azimuth angles 180°, −90°, and 90°. The experimentation is carried out at the Kovilpatti region (9º 11ʹN, 77º 52ʹE), Tamilnadu, India where the climatic conditions are hot and humid. The experiment is carried out at different mass flow rates of 0.004, 0.00625, and 0.00827 kg/s. The result revealed that the mass flow rate of 0.004 kg/s obtained the maximum temperature of 68°C on the flat roof, while the mass flow rate of 0.00625 and 0.00827 kg/s reached 50°C and 47°C between 14.00 hours. In the same way, the experimentation is carried out at the façade at different azimuth angles. Various parameters are analyzed, such as outlet water temperature, ambient temperature, incident solar radiation, thermal efficiency, and exergy efficiency. The mass flow rate of 0.00827 kg/s has yielded the highest efficiency on the façade and roof of the building.
AB - The performance of the solar water heater varies with respect to incident solar radiation, geographical location, and components of the solar water heater such as glazing, absorber material and storage tank. In this work, building-integrated solar water heating system (BISWHS) is fabricated and its output is evaluated by installing it on the roof and façade of the building for azimuth angles 180°, −90°, and 90°. The experimentation is carried out at the Kovilpatti region (9º 11ʹN, 77º 52ʹE), Tamilnadu, India where the climatic conditions are hot and humid. The experiment is carried out at different mass flow rates of 0.004, 0.00625, and 0.00827 kg/s. The result revealed that the mass flow rate of 0.004 kg/s obtained the maximum temperature of 68°C on the flat roof, while the mass flow rate of 0.00625 and 0.00827 kg/s reached 50°C and 47°C between 14.00 hours. In the same way, the experimentation is carried out at the façade at different azimuth angles. Various parameters are analyzed, such as outlet water temperature, ambient temperature, incident solar radiation, thermal efficiency, and exergy efficiency. The mass flow rate of 0.00827 kg/s has yielded the highest efficiency on the façade and roof of the building.
KW - BISWHS
KW - Building-integrated solar water
KW - concrete collector
KW - exergy efficiency
KW - thermal efficiency
UR - http://www.scopus.com/inward/record.url?scp=85101337829&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-85101337829&origin=recordpage
U2 - 10.1080/15435075.2021.1875468
DO - 10.1080/15435075.2021.1875468
M3 - RGC 21 - Publication in refereed journal
SN - 1543-5075
VL - 18
SP - 615
EP - 623
JO - International Journal of Green Energy
JF - International Journal of Green Energy
IS - 6
ER -