TY - JOUR
T1 - Electrochemically actuated microelectrodes for minimally invasive peripheral nerve interfaces
AU - Dong, Chaoqun
AU - Carnicer-Lombarte, Alejandro
AU - Bonafè, Filippo
AU - Huang, Botian
AU - Middya, Sagnik
AU - Jin, Amy
AU - Tao, Xudong
AU - Han, Sanggil
AU - Bance, Manohar
AU - Barone, Damiano G.
AU - Fraboni, Beatrice
AU - Malliaras, George G.
PY - 2024/7
Y1 - 2024/7
N2 - Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces. © The Author(s) 2024.
AB - Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces. © The Author(s) 2024.
UR - https://www.scopus.com/pages/publications/85191737784
UR - https://www.scopus.com/pages/publications/85191737784#tab=impact
UR - https://app-overton-io.ezproxy.cityu.edu.hk/articles.php?query=10.1038/s41563-024-01886-0
U2 - 10.1038/s41563-024-01886-0
DO - 10.1038/s41563-024-01886-0
M3 - RGC 21 - Publication in refereed journal
C2 - 38671159
SN - 1476-1122
VL - 23
SP - 969
EP - 976
JO - Nature Materials
JF - Nature Materials
IS - 7
ER -