Abstract
Objectives: The objective of this study was to quantify the changes in the diameter of the vertebral canal in the lumbosacral and sacrococcygeal column (L6–Co2) in cats in dorsal and ventral recumbency, simulating real body positioning during a perineal urethrostomy. Methods: Twenty-one male feline cadavers were enrolled in the study. All feline cadavers were evaluated by CT. Examinations were performed with the cadaver in a neutral position and dorsal and ventral recumbency. Sagittal vertebral canal diameters (VCDs) were obtained by measuring the distance between the ventral and dorsal aspects of the vertebral canal in the middle of the intervertebral space. Results: A comparison of the VCDs between L6 and L7, L7 and S1, S3 and Co1 and Co1 and Co2 in neutral position vs dorsal recumbency revealed a reduction of 0.27 mm (14.6%; P <0.001) between S3 and Co1 and 0.26 mm (18.1%; P <0.001) between Co1 and Co2. No differences were seen when comparing L6–L7 and L7–S1. The VCDs were decreased in all segments when comparing neutral with ventral recumbency. This study revealed a reduction of 0.13 mm between L6 and L7 (3.3%; P = 0.003), 0.14 mm between L7 and S1 (4.1%; P = 0.003), 0.61 mm between S3 and Co1 (32.5%; P <0.001) and 0.63 mm between Co1 and Co2 (44.1%; P <0.001). Comparison of the VCD between dorsal and ventral recumbency in L6–L7, L7–S1, S3–Co1 and Co1–Co2 revealed a decrease in the VCDs in ventral recumbency of 0.13 mm (3.3%; P <0.001), 0.12 mm (3.6%; P <0.001), 0.34 mm (21.0%; P <0.001) and 0.37 mm (31.7%; P <0.001), respectively. Conclusions and relevance: The results provide evidence that, from an anatomical point of view, perineal urethrostomy performed in dorsal recumbency is superior to ventral recumbency, but further clinical studies to verify these findings are necessary. © 2017, © The Author(s) 2017.
| Original language | English |
|---|---|
| Pages (from-to) | 38-44 |
| Journal | Journal of Feline Medicine and Surgery |
| Volume | 20 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - 1 Jan 2018 |
| Externally published | Yes |
Bibliographical note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].Fingerprint
Dive into the research topics of 'Effect of intraoperative positioning on the diameter of the vertebral canal in cats during perineal urethrostomy (cadaveric study)'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver