Skip to main navigation Skip to search Skip to main content

Dissolved organic matter (DOM) in recycled leachate of bioreactor landfill

  • Pin-Jing He
  • , Jun-Feng Xue
  • , Li-Ming Shao
  • , Guo-Jian Li
  • , Duu-Jong Lee

Research output: Journal Publications and Reviews › RGC 21 - Publication in refereed journal › peer-review

Abstract

Landfill leachate needs sufficient treatment before safe disposal. Bioreactor landfill technology could effectively degrade the organic matters in recirculated leachate, hence leaving a leachate stream of low biodegradability. This study characterized the dissolved organic matter (DOM) in the leachate from simulated bioreactor landfill columns with or without presence of trace oxygen. The removal efficiencies of this DOM using coagulation-sedimentation or electrolysis processes were demonstrated. Recirculated leachates were sampled from the simulated landfill columns applying conventional mode, intermittent-aeration mode, and natural aeration mode, whose DOM was fractionated into humic acids (HA), fulvic acids (FA) and hydrophilic fractions (HyI) by the XAD-8 resin combined with the cation exchange resin method. The recirculated leachate had low BOD/COD ratio, high humic substances contents, and high aromatic content. Their HA fraction comprised mainly large molecules (>10 k Da), while the FA and HyI were composed of smaller molecules (<50 k and <4 k Da, respectively). With the presence of oxygen, the TOC contents and the contents of HA, FA and HyI in leachate reduced, with FA and HyI fractions of molecular weight (MW) lower than 4 k Da more readily degraded. The organic matters left in leachates from intermittent-aeration mode and natural aeration mode were of low biodegradability. It was tested in the following sections the effects of coagulation-sedimentation process and of electrolysis process on the removal of residual DOM in recirculated leachate. Coagulation-sedimentation tests revealed that poly ferric sulphate (PFS) could remove more COD (58.1%) from leachate than polyaluminum chloride (PACl) (22.9%), particularly on the HA fraction with MW>10 k Da. Coagulation-sedimentation could not remove most of HyI in leachate. Furthermore, the corresponding BOD/COD ratio was not improved through coagulation. Electrolysis test could also effectively removed HA of MW>10 k Da. However, the biodegradability of treated effluent considerably was improved. The electrolysis could decompose high MW substances and increase biodegradability of recirculated leachate from bioreactor landfill. © 2006 Elsevier Ltd. All rights reserved.
Original languageEnglish
Pages (from-to)1465-1473
JournalWater Research
Volume40
Issue number7
DOIs
Publication statusPublished - Apr 2006
Externally publishedYes

Bibliographical note

Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 6 - Clean Water and Sanitation
    SDG 6 Clean Water and Sanitation
  2. SDG 12 - Responsible Consumption and Production
    SDG 12 Responsible Consumption and Production

Research Keywords

  • Coagulation
  • Electrolysis
  • Fulvic acids
  • Humic acids
  • Molecular weight
  • Recirculated leachate

Fingerprint

Dive into the research topics of 'Dissolved organic matter (DOM) in recycled leachate of bioreactor landfill'. Together they form a unique fingerprint.

Cite this