Skip to main navigation Skip to search Skip to main content

Development and characterization of an all-solid-state potentiometric biosensor array microfluidic device for multiple ion analysis

Wei-Yin Liao, Chen-Hsun Weng, Gwo-Bin Lee, Tse-Chuan Chou*

*Corresponding author for this work

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

Abstract

A microfluidic device with an all-solid-state potentiometric biosensor array was developed using microfabrication technology. The sensor array included a pH indicator, and potassium and calcium ion-selective microelectrodes. The pH indicator was an iridium oxide thin film modified platinum microelectrode and the iridium oxide was deposited by an electrochemical method. The potassium and calcium ion-selective microelectrodes were platinum coated with silicon rubber based ion-selective membranes with respectively potassium (valinomycin) and calcium (ETH 1001) ionophores. The detection system was integrated with a micro-pneumatic pump which can continuously drive fluids into the microchannel through sensors at flow rates ranging from 52.4 μl min-1 to 7.67 μl min-1. The sensor array microfluidic device showed near-Nernstian responses with slopes of 62.62 mV ± 2.5 mV pH -1, 53.76 mV ± 3 mV -log[K+]-1 and 25.77 mV ± 2 mV -log[Ca2+]-1 at 25°C ± 5°C, and a linear response within the pH range of 2-10, with potassium and calcium concentrations between 0.1 M and 10-6 M. In this study the device provided a convenient way to measure the concentration of hydrogen, potassium and calcium ions, which are important physiological parameters. © The Royal Society of Chemistry.
Original languageEnglish
Pages (from-to)1362-1368
JournalLab on a Chip
Volume6
Issue number10
DOIs
Publication statusPublished - 2006
Externally publishedYes

Bibliographical note

Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 9 - Industry, Innovation, and Infrastructure