Skip to main navigation Skip to search Skip to main content

Design of a dual-polarized wideband conformal loop antenna for capsule endoscopy systems

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

Abstract

This paper presents a dual-polarized conformal loop antenna for capsule endoscopy systems. The antenna is designed on the capsule shell, with two orthogonal counterparts to generate dual-polarized radiation. This design exhibits broad impedance bandwidths of 271 and 247 MHz for each port, covering the entire Medical Device Radiocommunications Service band as well as the 433.05-434.79 MHz Industrial Scientific Medical band. Due to the highly orthogonal current distributions of the proposed structure, an isolation of higher than 33 dB is achieved among the operating frequency bands in measurement. The dual-polarized antenna also shows an omnidirectional radiation property and a low cross-polarization level of around-40 dB, which helps to enhance communication quality, regardless of position and orientation. Whether other electronics and biocompatible coatings are included or an electromagnetic interference shielding is considered, the antenna still presents a robust performance. The cubic tissue phantom model is utilized for the initial design and optimization of the antenna structure. Moreover, the CST voxel human model is applied to study the conformal antenna in a realistic environment. Measurements are implemented using a solid tissue-mimicking phantom, and performances consistent with theoretical predictions are achieved. Finally, the wireless biotelemetry property is evaluated via the calculation of the communication link budget with an external antenna. © 2018 IEEE.
Original languageEnglish
Article number8424173
Pages (from-to)5706-5715
JournalIEEE Transactions on Antennas and Propagation
Volume66
Issue number11
DOIs
Publication statusPublished - 1 Nov 2018
Externally publishedYes

Bibliographical note

Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].

Research Keywords

  • Conformal antenna
  • dual polarization
  • loop antenna
  • wideband
  • wireless capsule endoscopy (WCE)

Fingerprint

Dive into the research topics of 'Design of a dual-polarized wideband conformal loop antenna for capsule endoscopy systems'. Together they form a unique fingerprint.

Cite this