Abstract
The use of LCL-filter for reducing current harmonics has been commonly used for converters connected to the power grid. However, under non-ideal power grid condition, a converter using an LCL-filter may interact with other converters connecting to the grid. In this paper, a three-phase voltage source converter using an LCL-filter is studied. Simulations show that resonant oscillation occurs in the distributed power grid, even if the voltage source inverter with LCL-filter is well designed. A small-signal loop analysis is performed to predict this stability problem and a method is proposed for stability design.
Original language | English |
---|---|
Title of host publication | Proceedings - 2014 International Power Electronics and Application Conference and Exposition |
Publisher | IEEE |
Pages | 114-119 |
ISBN (Electronic) | 9781479967681 |
ISBN (Print) | 9781479967674 |
DOIs | |
Publication status | Published - Nov 2014 |
Externally published | Yes |
Event | 2014 IEEE International Power Electronics and Application Conference and Exposition (IEEE PEAC' 2014) - Holiday Inn Shanghai Pudong Kangqiao, Shanghai, China Duration: 5 Nov 2014 → 8 Nov 2014 http://www.peac-conf.org |
Conference
Conference | 2014 IEEE International Power Electronics and Application Conference and Exposition (IEEE PEAC' 2014) |
---|---|
Abbreviated title | PEAC 2014 |
Country/Territory | China |
City | Shanghai |
Period | 5/11/14 → 8/11/14 |
Internet address |
Research Keywords
- Grid-connected inverter
- Interacting system
- Stability analysis
- Three-phase voltage source inverter