@inproceedings{d0e5a84b7a3f4237b51a2d0aa3d6a6e9,
title = "Crosstalk study in splitter PCB design of CAT-5 cabling applications",
abstract = "A review of crosstalk in splitter PCB design of CAT-5 cabling system for Local Area Network (LAN) application is carried out. Results have shown that design parameters such as separations, lengths and angles of trace pair are the critical parameters on the crosstalk reduction of PCB design, and that a 9dB reduction of the crosstalk is observed by simply balancing the mutual capacitance between trace pairs. {\textcopyright}2005 IEEE.",
keywords = "And coupling, Category cable, Crosstalk",
author = "Chan, \{K. H.\} and Chow, \{K. M.\} and Fung, \{L. C.\} and Leung, \{S. W.\} and Siu, \{Y. M.\}",
year = "2005",
doi = "10.1109/ISEMC.2005.1513646",
language = "English",
isbn = "0780393805",
volume = "3",
pages = "861--865",
booktitle = "IEEE International Symposium on Electromagnetic Compatibility",
note = "2005 International Symposium on Electromagnetic Compatibility, EMC 2005 ; Conference date: 08-08-2005 Through 12-08-2005",
}