Abstract
Critical crack tip opening displacement (CTODc) of concrete using experimental and analytical evaluation with seven different compressive strengths ranging from 30 up to 150 MPa was studied based on two types of fracture tests: three-point bending (TPB) and wedge splitting (WS). In the tests, the values of CTODc were experimentally recorded using a novel technique, in which fiber Bragg grating (FBG) sensors were used, and two traditional techniques, in which strain gauges and clip gauges were deployed. The values of CTODc of tested concrete were also predicted using two existing analytical formulae proposed by JENQ & SHAH and XU, respectively. It is found that the values of CTODc obtained by both experimental measurements and analytical formulae exhibit a negligible variation as the compressive strength of concrete increases, and the test geometry adopted has little impact on the value of CTODc. Regarding the experimental measurement of CTODc, the clip gauge method generally leads to a larger value of CTODc and shows a more significant scatter as compared with the other two methods, while the strain gauge method leads to a slightly lower CTODc as compared with the FBG sensor method. The analytical formula proposed by JENQ and SHAH is found to generally lead to an overestimation, while the analytical formula proposed by XU shows a good accuracy. © Central South University Press and Springer-Verlag Berlin Heidelberg 2011.
| Original language | English |
|---|---|
| Pages (from-to) | 1693-1699 |
| Number of pages | 7 |
| Journal | Journal of Central South University of Technology (English Edition) |
| Volume | 18 |
| Issue number | 5 |
| Online published | 1 Oct 2011 |
| DOIs | |
| Publication status | Published - Oct 2011 |
| Externally published | Yes |
Bibliographical note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].Funding
Foundation item: Project(50438010) supported by the Key Program of the National Natural Science Foundation of China; Project(JGZXJJ2006-13) supported by the Research and Application Programs of Key Technologies for Major Constructions in the South-North Water Transfer Project Construction in China Received date: 2010−07−29; Accepted date: 2010−11−29 Corresponding author: XU Shi-lang, Professor, PhD; Tel: +86−571−88208676; E-mail: [email protected]
Research Keywords
- Concrete
- Critical crack tip opening displacement (CTODc)
- Fiber Bragg grating (FBG) sensors
- High strength
- Three-point bending (TPB) tests
- Wedge splitting (WS) tests