Coordinated Control of UPQC for Mitigating Transient Voltage Fluctuations During Unintentional Islanding of Microgrid

  • Luyu Liu
  • , Yu Zheng
  • , Hongming Yang*
  • , Yan Xu
  • , Dangzhe Lv
  • , Zhaoyang Dong
  • *Corresponding author for this work

Research output: Journal Publications and Reviews › RGC 21 - Publication in refereed journal › peer-review

Abstract

To mitigate transient voltage fluctuations and current surges during unintentional islanding, this paper proposes a coordinated control strategy for an improved unified power quality conditioner (UPQC). The strategy coordinates the series converter, shunt converter, and common dc link during the transition from grid-connected to islanded operation. After islanding detection, an auxiliary bypass branch with bidirectional thyristor switches is activated to maintain the primary current path of the series transformer, enabling continuous series-voltage compensation for point of common coupling (PCC) voltage support. The series-side PI integrator is initialized according to the pre-switching operating state to avoid voltage-reference discontinuity. Meanwhile, a smoothed shunt-side current reference suppresses current surges caused by control-mode switching. To account for power coupling through the common dc link, the dc-link voltage deviation is introduced as a feedforward signal to correct the shunt-side power and current references, thereby reducing dc-link voltage fluctuations and converter interactions. Hardware-in-the-loop results under light-load, heavy-load, and reverse power-flow conditions validate the proposed strategy. The microgrid-side PCC voltage peaks are limited to 346.6 V and 339.7 V under light- and heavy-load conditions, respectively. Under reverse power flow, the transient current peak is reduced to 24.19 A, while the dc-link voltage minimum is increased to approximately 702 V and recovers smoothly within 0.15 s. These results demonstrate improved PCC voltage continuity, reduced transient current surges, and enhanced dc-link voltage stability during unintentional islanding.

© 2026 IEEE. All rights reserved, including rights for text and data mining and training of artificial intelligence and similar technologies. Personal use is permitted, but republication/redistribution requires IEEE permission.
Original languageEnglish
Number of pages12
JournalIEEE Transactions on Consumer Electronics
DOIs
Publication statusOnline published - 17 Jul 2026

Funding

This work was supported in part by the National Natural Science Foundation of China under Grants 72342001, 72371037, U25A20387, the science and technology innovation Program of Hunan Province under Grants 2025JJ10009, 2024RC9012, 2025RC9010, 2025RC4003, 2025QK1004, and the Changsha University of Science and Technology Grants No. CSUST-SKL202501.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Research Keywords

  • grid-connected/islanded transition
  • Microgrid
  • series-shunt coordinated control
  • transient voltage stability
  • Unified Power Quality Conditioner (UPQC)

Fingerprint

Dive into the research topics of 'Coordinated Control of UPQC for Mitigating Transient Voltage Fluctuations During Unintentional Islanding of Microgrid'. Together they form a unique fingerprint.

Cite this