Abstract
Arterial blood pressure Is one of the most important physiological parameters for the noninvasive diagnosis and monitoring of cardiovascular diseases. This study examines the relationships between arterial blood pressure and certain features of the photoplethysmographic (PPG) signals obtained from 15 young healthy subjects. Width of 1/2 pulse amplitude, width of 2/3 pulse amplitude, systolic upstroke time and diastolic time of the pulse were selected as features of the PPG signals. The experiment involved three sessions: rest, step-climbing exercise, and recovery from exercise. It was found that the diastolic time has higher correlation with systolic blood pressure (SBP) and diastolic blood pressure (DBP) than other features. The mean differences between the estimated and the measured blood pressure using a standard device are 0.21 mmHg for SBP and 0.02 mmHg for DBP. The corresponding standard deviations are 7.32 mmHg for SBP and 4.39 mmHg for DBP. The preliminary results indicate that it is possible to use the photoplethysmography only for cuffless and continuous estimation of arterial blood pressure.
| Original language | English |
|---|---|
| Title of host publication | PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY |
| Subtitle of host publication | A NEW BEGINNING FOR HUMAN HEALTH |
| Publisher | IEEE |
| Pages | 3153-3156 |
| Volume | 4 |
| ISBN (Print) | 0780377893 |
| DOIs | |
| Publication status | Published - Sept 2003 |
| Externally published | Yes |
| Event | 25th Annual International Conference of the IEEE-Engineering in Medicine and Biology Society - Cancun, Mexico Duration: 17 Sept 2003 → 21 Sept 2003 https://ieeexplore.ieee.org/xpl/conhome/9009/proceeding |
Publication series
| Name | PROCEEDINGS OF ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY |
|---|---|
| Publisher | Institute of Electrical and Electronics Engineers |
| Number | Part 1-4 |
| Volume | 25 |
| ISSN (Print) | 0589-1019 |
| ISSN (Electronic) | 1094-687X |
Conference
| Conference | 25th Annual International Conference of the IEEE-Engineering in Medicine and Biology Society |
|---|---|
| Place | Mexico |
| City | Cancun |
| Period | 17/09/03 → 21/09/03 |
| Internet address |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Research Keywords
- Blood pressure
- Noninvasive measurement
- Photoplethysmography
Fingerprint