Comparison of commercial real-Time reverse transcription-PCR assays for reliable, early, and rapid detection of heterologous strains of porcine reproductive and respiratory syndrome virus in experimentally infected or noninfected boars by use of different sample types

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

34 Scopus Citations
View graph of relations

Author(s)

  • Kevin O'Neill
  • Olajide Owolodun
  • Chong Wang
  • Karen Harmon
  • Jianqiang Zhang
  • Patrick G. Halbur
  • Lei Zhou
  • Xiang-Jin Meng
  • Tanja Opriessnig

Detail(s)

Original languageEnglish
Pages (from-to)547-556
Journal / PublicationJournal of Clinical Microbiology
Volume51
Issue number2
Publication statusPublished - Feb 2013
Externally publishedYes

Abstract

The aims of this study were to compare three commercial porcine reproductive and respiratory syndrome virus (PRRSV) realtime reverse transcription-PCR (RT-PCR) assays for detection of genetically diverse PRRSV isolates in serum, semen, blood swabs, and oral fluids collected from experimentally infected boars and to evaluate the effects of sample pooling. Six groups of three boars negative for PRRSV were each inoculated with one of six PRRSV isolates (sharing 55 to 99% nucleotide sequence identity in ORF5). Samples were collected on days-2, 1, 3, 5, 7, 14, and 21 postinoculation (p.i.) and tested by one of three commercially available real-time RT-PCR assays (VetMax from Applied Biosystems, Foster City, CA [abbreviated AB]; VetAlert from Tetracore, Rockville,MD[TC]; and AcuPig from AnDiaTec GmbH, Kornwestheim, Germany [AD]). At day 1 p.i., all assays detected at least one positive sample in each group. The highest detection rates were on days 3 and 5 p.i. Between days 1 and 7 p.i., serum samples had the highest detection rate (90%) with 100% agreement between tests, followed by blood swabs (kappa value of 0.97) and semen (kappa value of 0.80). Oral fluids had the lowest detection rates (AB, 55%; TC, 41%; AD, 46%) and the highest disagreement between kits (kappa value of 0.63). Pools of five samples did not reduce the detection rates if there was one positive sample with a large amount (cycle threshold,<30) of viral RNA in the pool. Serum and blood swab samples had shorter turnaround times for RNA extraction. The AB assay had a 1.6-times-shorter PCR time. In summary, serum and blood swabs had the best performance with highest detection rates and agreement between assays and the shortest turnaround times. Copyright © 2013, American Society for Microbiology.

Bibliographic Note

Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to lbscholars@cityu.edu.hk

Citation Format(s)