Can the timing-characteristics of phonocardiographic signal be used for cuffless systolic blood pressure estimation?

M. Y.M. Wong, C. C.Y. Poon, Y. T. Zhang*

*Corresponding author for this work

Research output: Chapters, Conference Papers, Creative and Literary WorksRGC 32 - Refereed conference paper (with host publication)peer-review

10 Citations (Scopus)

Abstract

Continuous and non-invasive measurement of blood pressure (BP) is always important to critically ill patients. To achieve continuous and cuffless BP monitoring, pulse transit time (PTT) has been reported as a potential parameter. Recently a novel parameter RS2 (defined as the time interval measured from the R wave of electrocardiographic (ECG) signal to the peak of second heart sound of phonocardiographic (PCG) signal) is proposed for the same purpose. 
In this study, the relationship between systolic BP (SBP) and PTT as well as the relationship between SBP and RS2 on 25 healthy subjects, aged 24±3 years, were compared after exercise. The results in current study showed that SBP is correlated with both PTT and RS2, where the mean individual correlations are r=-0.95 and r=-0.85 respectively. The mean standard deviation of the differences between the measured SBP and the SBP predicted from the regression lines in scatter plots of SBP-PTT and SBP-RS 2 are 4.1 mmHg and 7.2 mmHg respectively. In summary, the results showed that RS2 is possible to be used for continuous and non-invasive monitoring of SBP after exercise. In the future, it is important to investigate more robust techniques for locating characteristic points on the PCG signals.  
Original languageEnglish
Title of host publicationProceedings of the 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
PublisherIEEE
Pages2878-2879
ISBN (Print)1-4244-0032-5
DOIs
Publication statusPublished - Aug 2006
Externally publishedYes
Event28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS 2006) - New York, United States
Duration: 30 Aug 20063 Sept 2006

Publication series

NameAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
ISSN (Print)0589-1019

Conference

Conference28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS 2006)
Abbreviated titleEMBS 2006
PlaceUnited States
CityNew York
Period30/08/063/09/06

Fingerprint

Dive into the research topics of 'Can the timing-characteristics of phonocardiographic signal be used for cuffless systolic blood pressure estimation?'. Together they form a unique fingerprint.

Cite this