TY - JOUR
T1 - Behavior of electro-osmotic dewatering of biological sludge with salinity
AU - Chen, Guohua
AU - Lai, Keith C. K.
AU - Lo, Irene M. C.
N1 - Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].
PY - 2003
Y1 - 2003
N2 - The salinity effect on electro-osmosis dewatering was investigated by measuring the solid content of sludge after dewatering. Three levels of salinity were studied, 5,000, 10,000, and 12,500 ppm. Coagulant chemicals such as alum, ferrous sulfate, and organic polyelectrolytes were used for some tests. Increasing the salinity from 5,000 to 10,000 ppm and 10,000 to 12,500 ppm was found to increase the sludge solid content about 88 and 28%, respectively. A 2 V/cm increase in voltage intensity can also increase the solid content about 46%. The effect of chemicals is evident at low salinity. At 5,000 and 10,000 ppm, addition of chemicals in average can enhance the sludge solid content about 44 and 16%, respectively. Because of the electrolysis of salt solution and the release of chlorine gas, the pH of the sludge increased. Consequently the zeta potential of the sludge increased, which in turn results in an increase in dewatering rate. Therefore an S-shape solid content-time curve was observed for most of the operating conditions, contrary to the conventional shape of a linear increase followed with a decrease of rate before reaching zero rate.
AB - The salinity effect on electro-osmosis dewatering was investigated by measuring the solid content of sludge after dewatering. Three levels of salinity were studied, 5,000, 10,000, and 12,500 ppm. Coagulant chemicals such as alum, ferrous sulfate, and organic polyelectrolytes were used for some tests. Increasing the salinity from 5,000 to 10,000 ppm and 10,000 to 12,500 ppm was found to increase the sludge solid content about 88 and 28%, respectively. A 2 V/cm increase in voltage intensity can also increase the solid content about 46%. The effect of chemicals is evident at low salinity. At 5,000 and 10,000 ppm, addition of chemicals in average can enhance the sludge solid content about 44 and 16%, respectively. Because of the electrolysis of salt solution and the release of chlorine gas, the pH of the sludge increased. Consequently the zeta potential of the sludge increased, which in turn results in an increase in dewatering rate. Therefore an S-shape solid content-time curve was observed for most of the operating conditions, contrary to the conventional shape of a linear increase followed with a decrease of rate before reaching zero rate.
UR - http://www.scopus.com/inward/record.url?scp=0037224149&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-0037224149&origin=recordpage
U2 - 10.1081/SS-120017633
DO - 10.1081/SS-120017633
M3 - RGC 21 - Publication in refereed journal
SN - 0149-6395
VL - 38
SP - 903
EP - 915
JO - Separation Science and Technology
JF - Separation Science and Technology
IS - 4
ER -