Abstract
It is shown that the absorbed water moisture content in both nylon 6 and nylon 66 can be detected and assessed by differential scanning calorimetry. The absorbed water gives rise to a lower endothermic peak below 100°C. There is evidence that the absorbed water is not present solely in the amorphous regions. The amount of absorbed water moisture present could be estimated from the endotherms. © 1991.
| Original language | English |
|---|---|
| Pages (from-to) | 189-194 |
| Journal | Polymer Testing |
| Volume | 10 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - 1991 |
| Externally published | Yes |
Bibliographical note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].Publisher's Copyright Statement