TY - JOUR
T1 - An attempt to bridge muscle architecture dynamics and its instantaneous rate of force development using ultrasonography
AU - Li, Jizhou
AU - Zhou, Yongjin
AU - Zheng, Yong-Ping
AU - Li, Guanglin
N1 - Publisher Copyright:
© 2015 Elsevier B.V.
PY - 2015/8
Y1 - 2015/8
N2 - Muscle force output is an essential index in rehabilitation assessment or physical exams, and could provide considerable insights for various applications such as load monitoring and muscle assessment in sports science or rehabilitation therapy. Besides direct measurement of force output using a dynamometer, electromyography has earlier been used in several studies to quantify muscle force as an indirect means. However, its spatial resolution is easily compromised as a summation of the action potentials from neighboring motor units of electrode site. To explore an alternative method to indirectly estimate the muscle force output, and with better muscle specificity, we started with an investigation on the relationship between architecture dynamics and force output of triceps surae. The muscular architecture dynamics is captured in ultrasonography sequences and estimated using a previously reported motion estimation method. Then an indicator named as the dorsoventrally averaged motion profile (DAMP) is employed. The performance of force output is represented by an instantaneous version of the rate of force development (RFD), namely I-RFD. From experimental results on ten normal subjects, there were significant correlations between the I-RFD and DAMP for triceps surae, both normalized between 0 and 1, with the sum of squares error at 0.0516±0.0224, R-square at 0.7929±0.0931 and root mean squared error at 0.0159±0.0033. The statistical significance results were less than 0.01. The present study suggested that muscle architecture dynamics extracted from ultrasonography during contraction is well correlated to the I-RFD and it can be a promising option for indirect estimation of muscle force output.
AB - Muscle force output is an essential index in rehabilitation assessment or physical exams, and could provide considerable insights for various applications such as load monitoring and muscle assessment in sports science or rehabilitation therapy. Besides direct measurement of force output using a dynamometer, electromyography has earlier been used in several studies to quantify muscle force as an indirect means. However, its spatial resolution is easily compromised as a summation of the action potentials from neighboring motor units of electrode site. To explore an alternative method to indirectly estimate the muscle force output, and with better muscle specificity, we started with an investigation on the relationship between architecture dynamics and force output of triceps surae. The muscular architecture dynamics is captured in ultrasonography sequences and estimated using a previously reported motion estimation method. Then an indicator named as the dorsoventrally averaged motion profile (DAMP) is employed. The performance of force output is represented by an instantaneous version of the rate of force development (RFD), namely I-RFD. From experimental results on ten normal subjects, there were significant correlations between the I-RFD and DAMP for triceps surae, both normalized between 0 and 1, with the sum of squares error at 0.0516±0.0224, R-square at 0.7929±0.0931 and root mean squared error at 0.0159±0.0033. The statistical significance results were less than 0.01. The present study suggested that muscle architecture dynamics extracted from ultrasonography during contraction is well correlated to the I-RFD and it can be a promising option for indirect estimation of muscle force output.
KW - Image processing
KW - Motion estimation
KW - Muscle contraction
KW - Rate of force development
KW - Ultrasound
UR - http://www.scopus.com/inward/record.url?scp=84929607589&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-84929607589&origin=recordpage
U2 - 10.1016/j.ultras.2015.03.009
DO - 10.1016/j.ultras.2015.03.009
M3 - RGC 21 - Publication in refereed journal
C2 - 25911147
AN - SCOPUS:84929607589
SN - 0041-624X
VL - 61
SP - 71
EP - 78
JO - Ultrasonics
JF - Ultrasonics
ER -