Abstract
This paper provides some qualitative insights into, and a quantitative analysis of, the interrelationship between the ballast circuit parameters and the physical processes inside the lamp arc under dimming conditions. Qualitative explanation is supported by experimental observations on the dimming characteristics of fluorescent and high-intensity-discharge (HID) lamps. This understanding enables engineers to choose the right combination of dimming technique and electronic ballast topology for different types of discharge lamps. Verified by experiments, the fundamental approximation technique is used to characterize the frequency-control and voltage-control dimming technique for series-loaded and parallel-load resonant circuits. © 2005 IEEE.
| Original language | English |
|---|---|
| Pages (from-to) | 1432-1440 |
| Journal | IEEE Transactions on Power Electronics |
| Volume | 20 |
| Issue number | 6 |
| DOIs | |
| Publication status | Published - Nov 2005 |
Bibliographical note
Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].Funding
This work was supported by the Hong Kong Research Grant Council under CERG Contract CityU 1156/00E
Research Keywords
- Ballast circuit parameters
- High-intensity-discharge (HID) lamps
- Lamp arc
RGC Funding Information
- RGC-funded
Fingerprint
Dive into the research topics of 'An analysis into the dimming control and characteristic of discharge lamps'. Together they form a unique fingerprint.Cite this