TY - JOUR
T1 - Adaptive response in zebrafish embryos induced using microbeam protons as priming dose and X-ray photons as challenging dose
AU - Choi, Viann Wing Yan
AU - Konishi, Teruaki
AU - Oikawa, Masakazu
AU - Iso, Hiroyuki
AU - Cheng, Shuk Han
AU - Yu, Kwan Ngok
PY - 2010/11
Y1 - 2010/11
N2 - In the studies reported here, a high-linear-energy-transfer (high-LET)-radiation dose was used to induce adaptive response in zebrafish embryos in vivo. Microbeam protons were used to provide the priming dose and X-ray photons were employed to provide the challenging dose. The microbeam irradiation system (Single-Particle Irradiation System to Cell, acronym as SPICE) at the National Institute of Radiological Sciences (NIRS), Japan, was employed to control and accurately quantify the number of protons at very low doses, viz., about 100 μGy. The embryos were dechorionated at 4 h post fertilization (hpf) and irradiated at 5 hpf by microbeam protons. For each embryo, ten irradiation points were arbitrarily chosen without overlapping with one another. To each irradiation point, 5, 10 or 20 protons each with an energy of 3.4 MeV were delivered. The embryos were returned back to the incubator until 10 hpf to further receive the challenging exposure, which was achieved using 2 Gy of X-ray irradiation, and then again returned to the incubator until 24 hpf for analyses. The levels of apoptosis in zebrafish embryos at 25 hpf were quantified through terminal dUTP transferase-mediated nick end-labeling (TUNEL) assay, with the apoptotic signals captured by a confocal microscope. The results revealed that 5 to 20 protons delivered at 10 points each on the embryos, or equivalently 110 to 430 μGy, could induce radioadaptive response in the zebrafish embryos in vivo.
AB - In the studies reported here, a high-linear-energy-transfer (high-LET)-radiation dose was used to induce adaptive response in zebrafish embryos in vivo. Microbeam protons were used to provide the priming dose and X-ray photons were employed to provide the challenging dose. The microbeam irradiation system (Single-Particle Irradiation System to Cell, acronym as SPICE) at the National Institute of Radiological Sciences (NIRS), Japan, was employed to control and accurately quantify the number of protons at very low doses, viz., about 100 μGy. The embryos were dechorionated at 4 h post fertilization (hpf) and irradiated at 5 hpf by microbeam protons. For each embryo, ten irradiation points were arbitrarily chosen without overlapping with one another. To each irradiation point, 5, 10 or 20 protons each with an energy of 3.4 MeV were delivered. The embryos were returned back to the incubator until 10 hpf to further receive the challenging exposure, which was achieved using 2 Gy of X-ray irradiation, and then again returned to the incubator until 24 hpf for analyses. The levels of apoptosis in zebrafish embryos at 25 hpf were quantified through terminal dUTP transferase-mediated nick end-labeling (TUNEL) assay, with the apoptotic signals captured by a confocal microscope. The results revealed that 5 to 20 protons delivered at 10 points each on the embryos, or equivalently 110 to 430 μGy, could induce radioadaptive response in the zebrafish embryos in vivo.
KW - Adaptive response
KW - Danio rerio
KW - Microbeam
KW - Protons
KW - Zebrafish embryos
UR - http://www.scopus.com/inward/record.url?scp=78649785943&partnerID=8YFLogxK
UR - https://www.scopus.com/record/pubmetrics.uri?eid=2-s2.0-78649785943&origin=recordpage
U2 - 10.1269/jrr.10054
DO - 10.1269/jrr.10054
M3 - RGC 21 - Publication in refereed journal
C2 - 21116099
SN - 0449-3060
VL - 51
SP - 657
EP - 664
JO - Journal of Radiation Research
JF - Journal of Radiation Research
IS - 6
ER -