TY - GEN
T1 - A controllable micro-lens structure for bio-analytical applications
AU - Hsiung, Suz-Kai
AU - Lee, Gwo-Bin
N1 - Publication details (e.g. title, author(s), publication statuses and dates) are captured on an “AS IS” and “AS AVAILABLE” basis at the time of record harvesting from the data source. Suggestions for further amendments or supplementary information can be sent to [email protected].
PY - 2007
Y1 - 2007
N2 - In this study, a new and simple design of a controllable micro-lens structures capable of the enhancement of laser induced fluorescence (LIF) system has been demonstrated. Two pneumatic side-chambers were placed between a micro sample flow channel and an optic fiber channel. The interval between the side-chamber and the micro sample channel was used to form a controllable micro-lens structure. A deformation of the micro-lens structure can be generated after a pressurized index-matching fluid was injected into the pneumatic side-chambers. The side-chambers can be deflected as a convex lens to focus both the laser light source and the fluorescence emission. The profile and the focal length of the micro-lens structure can be adjusted by using different applied pressures accordingly so that bio-samples with a low concentration can be detected. Using low-cost polymeric materials such as polydimethylsiloxane (PDMS), rapid and reliable fabrication techniques involving standard lithography and replication process was employed for the formation of the proposed chip device. Finally, experimental results clearly revealed the micro-lens structure can be deformed as a convex lens to focus the laser light source and the fluorescence signal can be enhanced successfully. The developed device has a great potential to be integrated with other microfluidic devices for further biomedical applications. © 2007 IEEE.
AB - In this study, a new and simple design of a controllable micro-lens structures capable of the enhancement of laser induced fluorescence (LIF) system has been demonstrated. Two pneumatic side-chambers were placed between a micro sample flow channel and an optic fiber channel. The interval between the side-chamber and the micro sample channel was used to form a controllable micro-lens structure. A deformation of the micro-lens structure can be generated after a pressurized index-matching fluid was injected into the pneumatic side-chambers. The side-chambers can be deflected as a convex lens to focus both the laser light source and the fluorescence emission. The profile and the focal length of the micro-lens structure can be adjusted by using different applied pressures accordingly so that bio-samples with a low concentration can be detected. Using low-cost polymeric materials such as polydimethylsiloxane (PDMS), rapid and reliable fabrication techniques involving standard lithography and replication process was employed for the formation of the proposed chip device. Finally, experimental results clearly revealed the micro-lens structure can be deformed as a convex lens to focus the laser light source and the fluorescence signal can be enhanced successfully. The developed device has a great potential to be integrated with other microfluidic devices for further biomedical applications. © 2007 IEEE.
UR - https://www.scopus.com/pages/publications/50149121147
UR - https://www.scopus.com/pages/publications/50149121147#tab=impact
U2 - 10.1109/memsys.2007.4433174
DO - 10.1109/memsys.2007.4433174
M3 - RGC 32 - Refereed conference paper (with host publication)
SN - 1424409519
SN - 9781424409518
T3 - Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)
SP - 763
EP - 766
BT - Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007
T2 - 20th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2007
Y2 - 21 January 2007 through 25 January 2007
ER -