Skip to main navigation Skip to search Skip to main content

核电厂厂用水系统概率安全分析方法研究

Translated title of the contribution: Study on Probabilistic Safety Analysis for Service Water System of Nuclear Power Plant
  • 曾令刚
  • , 李波
  • , 赵军*
  • , 王伟
  • *Corresponding author for this work

Research output: Journal Publications and ReviewsRGC 21 - Publication in refereed journalpeer-review

Abstract

[Introduction]The service water system as the ultimate heat sink is of great significance for the operation and accident mitigation of nuclear power plants.[Method]In this paper,the fault tree was built to model the full power and shutdown modes of the investigated plant under cold and non-cold weather conditions respectively,and then to assess the reliability of service water system as an accident mitigation measure. The Monte Carlo method was used to analyse the operability of the system as an initiating event. Relationships between equipment failure rate,maintenance cycle and the annual average unavailability were also attained via sensitivity analysis. [Result] Quantitative results show the failure rates of service water system for different mission time, particularly under the conditions of non-cold weather at full power the failure rates are 1. 47E-01 per year and 4. 10E-04 per 72 hours (mission time in accident mitigation process),and at shutdown mode the corresponding failure rate is 6. 45E-03 per 96 hours. The frequency of the loss of service water is about 2. 0E-03 per year and the annual average unavailability time of the system is about 3. 4 hours.[Conclusion]The results suggest that seawater pretreatment system has more significant influence on the unreliability of service water system,of which the operation failure of electric isolation valve at the main pipeline is the dominant contributor due to having no redundant design. In addition,shortening regular maintenance cycle will be a more effective and operable way to reduce the annual average unavailability time compared with reducing the failure rates of components.
Translated title of the contributionStudy on Probabilistic Safety Analysis for Service Water System of Nuclear Power Plant
Original languageChinese (Simplified)
Pages (from-to)132-140
Journal南方能源建设
Volume7
Issue number2
DOIs
Publication statusPublished - Jun 2020

Bibliographical note

Full text of this publication does not contain sufficient affiliation information. With consent from the author(s) concerned, the Research Unit(s) information for this record is based on the existing academic department affiliation of the author(s).

Research Keywords

  • 厂用水系统
  • 概率安全分析
  • 故障树方法
  • 蒙特卡罗方法
  • service water system
  • probabilistic safety analysis
  • fault tree analysis
  • monte carlo method

Fingerprint

Dive into the research topics of 'Study on Probabilistic Safety Analysis for Service Water System of Nuclear Power Plant'. Together they form a unique fingerprint.

Cite this