Abstract
This paper presented the analysis results based on the field measurement data of wind velocity and acceleration of main tower in CITIC Plaza during Typhoon Damrey. The results revealed that turbulence intensity of Typhoon Damrey was larger than the normal, and the across-wind dynamic response of CITIC Plaza approached the along-wind dynamic response under Typhoon Damrey. Meanwhile, the correlation of wind characteristic and wind-induced structure vibrations was investigated in selected different time intervals. The research indicated that 3-minute mean wind speed was reasonable in calculating the wind load and the wind-induced response.
| Translated title of the contribution | Correlation analysis of wind characteristic and wind-induced response of CITIC Plaza |
|---|---|
| Original language | Chinese (Simplified) |
| Pages (from-to) | 21-27 |
| Journal | 实验流体力学/Journal of Experiments in Fluid Mechanics |
| Volume | 23 |
| Issue number | 4 |
| Publication status | Published - Dec 2009 |
Research Keywords
- 风场特性
- 风致响应
- 现场实测
- 相关性
- 基本时距
- Wind field characteristic
- Wind-induced response
- Field measurement
- Correlation
- Time interval
Fingerprint